Baur/HVT Frida – VLF Tester and Diagnostics Device

Brand:
Please, activate Wishlist option to use this widget.
Please, activate Compare option to use this widget.
24 people are viewing this product right now

Shipping calculated at checkout.
Add to quote
Estimated delivery:5 days

High voltage VLF tester Up to 26.1 kVrms, 34 kV peak

Frida and Frida TD

  • Frida VLF Tester and Diagnostics Devices
  • High voltage VLF tester Up to 34 kV peak
  • Cable testing and dissipation factor diagnostics in one device
  • Easy and quick test setup
  • Automatic testing and diagnostic sequences
  • Compact dimensions and lightweight
  • Max. test voltage 24 kVrms / 34 kVpeak
  • Voltage shapes: VLF truesinus ®, VLF square wave voltage, and DC voltage
  • VLF truesinus® test technology enables  load-independent, reproducible sinusoidal high voltage
  • Cable testing according to: DIN VDE 0276-620/621 (CENELEC HD 620/621), IEEE 400-2012, IEEE 400.2-2013, IEC 60060-3
  • Cable sheath testing according to IEC 60502/ IEC 60229
  • Voltage withstand test on electrical equipment according to IEEE 433

Frida TD

  • Dissipation factor testing of electrical equipment and medium-voltage cables up to 20 kV
  • Highly precise dissipation factor measurement with a precision of 1 x 10-4
  • Detection of leakage currents using VSE box (option)
  • Better overview of the cable condition with Full Monitored Withstand Test in combination with the PD-TaD 60
  • Full MWT = VLF cable testing with parallel dissipation factor and partial discharge measurement
  • Fully automated and individually programmable diagnostic sequences including evaluation
SKU: BAUR/HVT Frida Tags: , Categories:
Pay safely with Visa Pay safely with Master Card Pay safely with PayPal Pay safely with Maestro Tooltip text
Guarantee Safe and Secure Payment Checkout

Description

BAUR/HVT Frida – VLF Tester and Diagnostics Device

BAUR/HVT Frida - VLF Tester and Diagnostics Device
  • High voltage VLF tester and integrated tan delta diagnostics device Up to 60 kV peak
  • Cable testing and dissipation factor diagnostics in one device
  • Fully automated and individually programmable diagnostic sequences including evaluation
  • Detection of leakage currents using VSE box (option)
  • Highly precise dissipation factor measurement with precision of 1 x 10-4

The portable BAUR viola and viola TD devices are used for:

  • Testing medium-voltage cables and electrical equipment (generators, transformers and switch gear)
  • Cable sheath testing
  • Cable diagnostics (viola TD):
    • Dissipation factor measurement and Monitored Withstand Test with tan δ
    • Partial discharge measurement*
    • Full Monitored Withstand Test with tan δ and partial discharge measurement*

The VLF testing makes it possible to locate insulation faults in plastic and paper in zulated mass-impregnated cables in the shortest of testing times without impairing the quality of the surrounding insulating material.

The dissipation factor diagnostics with 0.1 Hz VLF truesinus® provides differentiated information on the ageing condition of paper-insulated mass-impregnated and PE/XLPE cables. In the case of PE/XLPE cables, the dissipation factor measurement is capable of differentiating between new, slightly or severely “water tree”-damaged cables. This makes it possible to prioritize the need to replace cables.

The Monitored Withstand Test with tan delta combines the cable testing and dissipation factor measurement, allowing an accurate and comprehensive assessment of the cable condition. In addition, there is minimum load on the cable due to the optimized test duration.

Diagnostic Reporter – Sample log (extract)
Diagnostic Reporter – Sample log (extract)

General Information

  • Data transfer via USB interface
  • Management of test and measurement data with PC software
  • Automatic discharge unit
  • Optionally expandable
  • viola: to a PD diagnostics system
  • viola TD: to a PD and full MWT diagnostics system
Full Monitored Withstand Test

Combination of methods for more significant information

With the BAUR viola TD VLF tester and diagnostics device and in combination with the PD-TaD 60 PD portable diagnostics system, you can measure dielectric losses and test the cable route for partial discharges during the VLF cable testing. This combination of methods is called Full MWT and provides significantly more information than the cable test alone. While the cable test shows whether the cable system can withstand a load over a specified test duration, the dissipation factor measurement enables an evaluation of the condition of the cable insulation. Moreover, a partial discharge measurement shows and locates the PD faults precisely. The highlight of MWT is the condition-based test duration: Provided it is permitted, the test duration can be shortened, which in turn lowers costs. This way, the cable is only exposed to the increased test voltage for the required duration.

Combination of methods for more significant information
VLF truesinus ® – A voltage shape for all methods and method combinations

VLF truesinus® is the only voltage shape that enables both the reliable voltage tests as well as precise dissipation factor and partial discharge measurements. Unlike other voltage shapes, the VLF truesinus® voltage is load-independent, symmetrical and continuous. This is a prerequisite for high precision as well as reproducibility and comparability of measurement results.

Product General Attributes

Shipping Weight88 LBS

Reviews

There are no reviews yet.

Be the first to review “Baur/HVT Frida – VLF Tester and Diagnostics Device”

Manuals/Guides

Baur/HVT Frida – VLF Tes...

Our team of knowledgeable professionals is here to help you make informed decisions. Whether you need product recommendations, technical support, or guidance on your purchase, we're just a click away.

Contact Us Now:
📧 sales@nestesinstruments.com
📞 +1 (833) 763-7837


Let us assist you in finding the perfect solution!
Have Questions? Ask an Expert!