Instek DAQ-903 – 40-Channel Single-Ended Multiplexer
The Instek DAQ-903 can switch 40 single-wire inputs per module. It can be used for common-low applications such as battery testing, component characterization, and desktop testing. The low voltage connection is isolated from the ground and can be floated up to 300 V. DAQ-903 also supports all 2-wire internal measurements except current.
Please note: this item is only a module – mainframe is sold separately.
Several versions available
Instek offers several modules for use with its DAQ-9600 mainframe. The information below provides an overview of the main specifications for each. For more detailed information, please click here.
DAQ-900
- 20-Channel Universal Multiplexer (Solid State Relay)
- Scanning speed up to 450 channels per second
- 2-wire and 4-wire scanning
- Built-in temperature cold junction reference
- 120V switching
DAQ-901
- 20+2 Channels Universal Multiplexer (Armature Relay)
- Scanning speed can reach 80 channels per second
- 2-wire and 4-wire scanning
- Built-in temperature cold junction reference
- 300V switching
- The extra 2 channels can directly measure current (1A/per CH)
DAQ-903
- 40-Channel Single-Ended Multiplexer
- Scanning speed can reach 80 channels per second
- Single-wire switching is suitable for common-low applications
- Built-in temperature cold junction reference
DAQ-904
- 4 x 8 2-Wire Matrix
- 3ms switching speed
- 32 2-wire intersections
- 300V, 1A switching
- Up to 96 crosspoints (3 slots)
DAQ-909
- 8+2 Channels High Voltage High Current Multiplexer
- 3ms switching speed
- DC voltage 600V, current 2A
- 2-wire and 4-wire scanning
- Additional 2 channels can directly measure current (2A/per channel)
Internal DMM measurement functions supported
| DAQ-900 | DAQ-901 | DAQ-903 | DAQ-904 | DAQ-909 | |
| AC/DC Voltage | ✓² ³ | ✓ | ✓ | ✓ | |
| AC/DC Current | ✓ | ✓ | |||
| Freq./Period | ✓ | ✓ | ✓ | ✓ | |
| 2-Wire Resistance | ✓¹ | ✓ | ✓ | ✓ | |
| 4-Wire Resistance | ✓¹ | ✓ | ✓ | ||
| Thermocouple | ✓ | ✓ | ✓ | ||
| 2-Wire RTD | ✓ | ✓ | ✓ | ||
| 4-Wire RTD | ✓ | ✓ | |||
| Transistor | ✓ | ✓ | ✓ | ||
| Capacitance | ✓ | ✓ | ✓ |
Note:
1. For the measurement of 100Ω and 1kΩ resistance ranges, it is recommended to use 4-wire resistance. The maximum resistance range of DAQ-900 is 1MΩ.
2. When measuring AC voltage, the input impedance will decrease with frequency. A source impedance of 5Ω or less will maintain specification over frequency. A source impedance of 50Ω or less will maintain specification in the 5 kHz range.
3. For DC voltage measurement, if the integration time is short and the source impedance is high, more stabilization time may be required.