Description
NK AT2-420-24L-FT AT Series Current Transducers

- 100, 150, 200A Full Scale Range
- 4-20mA Output Signal
- 24VDC Loop-powered (4–20mA output only) Power Supply
- Solid-core case style, Top Term.
AT Series Current Transducers combine a current transformer and signal conditioner into a single package. The AT Series has jumper selected current input ranges and industry standard 4-20mA, 0-5VDC or 0-10VDC outputs. The AT Series is designed for application on ‘linear’ or sinusoidal AC loads. Available in a split-core case or two types of solid-core cases.
Designed to provide an analog current reading for monitoring, data logging and panel meter applications, these transducers offer a choice of 0-5VDC, 0-10VDC or 4-20mA average responding or True RMS outputs. Self-powered and split-core options make these a cost-effective choice as a PLC input in motor status applications or where VFDs are involved.
Connections
Notes: Pressure plate screw terminals. 12-22 AWG solid or stranded. Field adjustable setpoint.

Current Sensors/Current Transducers Template | |
---|---|
Maximum Current | 200 A |
Adjustable Output | No |
Accuracy | 1% FS |
Response Time | 300 MILISECONDS (0.3 s) |
Power Supply (Current Sensor) | VDC |
Aperture Size | 19 MM |
Product General Attributes | |
Product Height | 2.30 IN |
Product Length | 4.75 IN |
Product Width | 3.25 IN |
HTS/Schedule B Number | 8536.50.7000 |
ECCN Number | EAR99 |
Country of Origin | United States |
Shipping Height | 2.30 IN |
Shipping Length | 4.75 IN |
Shipping Width | 3.25 IN |