Description
TREND Networks R164064 – FiberTEK III LC Rx Connector

One-jumper Calibration
- Choose desired test standard in LanTEK.
- Collect 2 x LC-SC and 2 x LC-LC test cords. Clean and inspect each connector.
- Attach LC end to Rx port and SC end to Tx port of each module.
- Select Field Calibration from home screen.
- Press 1 Jumper (F2) calibration mode.
- Press Start (F1) icon to begin.

Bi-directional Test Step 1
- Disconnect test cord from Rx port of each module. Do not disturb connector at Tx port.
- Attach an LC-LC test cord to the Rx port of each module.
- Connect test cords to cable under test after cleaning the connectors of cable under test.
- Run Autotest.
Measured loss includes the connection at the end of the test cords, the cord on the Rx port and the cable under test.

Bi-directional Test Step 2
- Reverse the test cord connections at both ends of the cable under test.
- Do not remove the connections to the FiberTEK III adapters, this will void the calibration.
- Press Continue (F1) to resume the test. The results for both fibers in each direction will be displayed at test completion.