Description
Graphtec GL100-N-TH-DPA-CO2 – Data Logger with Temp/Humidity and CO2 Sensor
- Easy measurement by multifunction input
- Available the software for PC & Smart devices
- Possible to check the data in multiple method
- Reliable measurement with useful functions
- Typical applications
- Sales network
The Graphtec GL100-N-TH-DPA-CO2 is modular type that is able to support variety measurement by exchanging the input module. Multiple sensors and the input terminal are available for corresponding to the application.
Easy measurement by multifunction input
The input module can be expanded to accommodate a wide variety of measurements

Dual port adapter connects up to two modules for simultaneous interface

GL100-WL / N
- Dual port adapter
- Temp./Humidity sensor
- Illuminance/UV sensor

GL100-WL / N
- Dual port adapter
- Temp./Humidity sensor
- Carbon dioxide sensor

GL100-WL / N
- Dual port adapter
- Illuminance/UV sensor
- Carbon dioxide sensor
Providing a variety of sensors and input terminals corresponding to the application.
There is the following input module.
Number of channels and measurement type are fixed with each input module.
| Sensor | |||
| No. | Input module | Measurement (actual sensing) | Measurement (calculated value) |
| 1 | Temp./Humidity sensor GS-TH | Temperature (-20 to 85 ºC), Humidity (0 to 100 % RH) | Accumulated temperature, Dew-point temperature |
| 2 | Acceleration/Temp. sensor GS-3AT | Acceleration in 3-axis (max. 10 G), Temperature (-10 to 50 ºC) | N/A |
| 3 | Illuminance/UV sensor GS-LXUV | Illuminance (max. 200 k lx), UV intensity (max. 30 mW/cm2) | Accumulated Illuminance, Accumulated UV intensity |
| 4 | Carbon dioxide sensor GS-CO2 | CO2 concentration (max. 9999 ppm) | N/A |
![]() | |||
| Input terminals / Adapter | |||
| No. | Input module | Measurement (actual sensing) | Measurement (calculated value) |
| 5 | Voltage/Temp. input module GS-4VT | Voltage (max. 50 V) or Temp. (TC: K/T type) of 4 ch, Logic or Pulse of 4 ch | |
| 6 | Temperature input terminal GS-4TSR | Thermistor (max. 120 ºC) of 4 ch, Logic or Pulse of 4 ch | |
| 7 | Thermistor sensor GS-103AT-4P | Temperature sensor (-40 to 105 ºC), Normal type use with GS-4TSR module | |
| 8 | Thermistor sensor GS-103JT-4P | Temperature sensor (-40 to 120 ºC), Ultrathin type use with GS-4TSR module | |
| 9 | AC current sensor adapter GS-DAP-AC | AC current, 2 sensors are able to connect (*1) | Power (instantaneous), Integrated power (Electric energy) |
| 10 | AC current sensor GS-AC50A | Clamp-on type (max. 50 A AC), use with GS-DAP-AC module | |
| 11 | AC current sensor GS-AC100A | Clamp-on type (max. 100 A AC), use with GS-DAP-AC module | |
| 12 | AC current sensor GS-AC200A | Clamp-on type (max. 200 A AC), use with GS-DAP-AC module | |
| *1: it is required to use the same type sensor and it is used in the same power system of the single- or three-phase. | |||
![]() | |||
Packages will include combined models best suited for your application
GL100 will feature package solutions that combines several sensors and modules together for a one stop solution as an out-of-box-ready item for the specific application that best fits your need.
Combo models for GL100-WL | Temp./Humidity Set: GL100-WL-TH GL100-WL & GS-TH
| Acceleration Set: GL100-WL-3AT GL100-WL & GS-3AT
| Voltage/Temp. Set: GL100-WL-4VT GL100-WL & GS-4VT
| Thermistor Set: GL100-WL-4TSR GL100-WL & GS-4TSR
|
Combo models for GL100-N | Temp./Humidity Set: GL100-N-TH GL100-N & GS-TH
| Acceleration Set: GL100-N-TH GL100-N & GS-3AT
| Voltage/Temp. Set: GL100-N-4VT GL100-N & GS-4VT
| Thermistor Set: GL100-N-3TSR GL100-N & GS-3TSR
|
Available the software for PC & Smart devices
The GL100 is able to use with the PC or the Smart devices. The data on the GL100 can be monitored using the software.

General-purpose software for PC
General purpose application software will continue to have the ability to view in Y-T chart, waveform, and digital values. It is able to be also controlled the GL100 in real-time.

General-purpose software for the Smart devices
General purpose application software has the ability to view in Y-T chart and digital values. The displayed information will be refreshed by request. The simple settings of GL100 are able to control.
*It is available for the Android OS and the iOS in the Google Play or App Store.
Supported OS : Android 4.1 to 6.0, iOS 7 / 8 / 9 (up to 9.3.4)
The most recent captured data is displayed in the digital value, trend graph or the alarm history. It is updated by operation of synchronous.

Industry-specific software (for PC and Smart device)
The new industry-specific customize software will feature targeted software in accommodating users with indicators that are specific and familiar to that industry.
Agriculture Indicators of plant growth | Logistics Indicators of safe transportation and storage | Power Indicators of electric energy |
* It is available to download at the autumn of 2014
| Specific-industry | Measurement capability | Description |
| Agriculture | • Temperature Accumulation • Humidity Deficit • Amount of solar radiation • Amount of ultraviolet rays | Confirm temperature accumulation, humidity deficit, solar radiation, ultraviolet rays as part of the vital indicators for healthy plant growth. Measure optimal saturation deficit by understanding the best conditions applied for growth, flowering, and fruiting using temperature accumulation and optimal growth environment scheme. |
| Logistics | • Search and display acceleration thresholds • Temperature Accumulation • Humidity Deficit | Transpiration of industrial equipment, temperature controlled transport of food, and warehouse temperature management can all be monitored to provide the safest and secured operation. Safety measurements through monitoring the vibration of the transport vehicles can be vital to heavy-industrial and vibration sensitive equipment. Accumulated temperature monitoring and humidity levels will be vital to keeping food fresh in a controlled environment. |
| Power measurement | • AC current • Power • Integrated power | Power and electric energy levels will be displayed on the graph using measured AC current locally at the factory, buildings and industrial equipment. Corresponds to three power systems including two-wire single-phase, three-wire single-phase, or three-wire in three-phase. |
Possible to check the data in multiple method
Wireless access will support multiple configurations for both secured and world wide internet access.
The following configuration is available to communicate with the GL100. The available function varies by the configuration.
| Configuration Case 1 | Configuration Case 2 *1 |
Direct connection (peer-to-peer) with no LAN connection![]() | Local area network (LAN) with no Internet connection![]() |
| Configuration Case 3 *1 | |
Local area network (LAN) with Internet connection![]() | |
| Available functions | Configuration Case 1 | Configuration Case 2 | Configuration Case 3 | |||||
| PC (#1) | Smart device (#1) | PC (#2) *1 | Smart device (#2) | PC (#3) *1 | Smart device (#3) | PC (#4) | Smart device (#4) | |
| Control of full functions | Ο | Ο | Ο | Δ*2 | ||||
| Control of simple functions (Start/Stop, Sampling, Alarm) | Ο | Ο | Ο | Δ*2 | ||||
| Display Waveform/Digital value | Ο | Ο | Ο | Ο | Ο | Ο | Δ*2 | Δ*2 |
| Save data to PC | Ο | Ο | Ο | Δ*2 | ||||
| Receive message via email | Ο | Ο | Ο | Ο | ||||
Ο:Function is available. Δ:Function is available in the condition.
Note:
*1: Multiple PC cannot make connection to the same GL100 simultaneously.
*2: Assign a static global IP. Or DDNS service must be available within network and the GL100 configured as a device within the WAN.
- When the router has the static IP address, it is able to access from the Internet (WAN) using the static IP address.
- When the DDNS (Dynamic Domain Name Server) is used, the ISP provide the DDNS service and the router supports the DDNS. The router will have the domain name. It is able to access from the Internet (WAN) using the domain name.
Product General Attributes | |
|---|---|
| Country of Origin | Japan |









Reviews
There are no reviews yet.