Description

BK Precision 2709B
- Magnetic hanger & One-handed operation
- True RMS
- Large easy-to-read LCD with backlight | Auto/manual ranging | Auto power off
- DC voltage to 1000 V
- Measures up to 10 A (AC & DC)
Auto Ranging True RMS Tool Kit Digital Multimeter
The 2709B is a full featured auto ranging true RMS DMM that combines performance, value and functionality. The 6600 count LCD has a green back light that allows the meter to be used in dimly lit environments. The 2709B can measure resistance values up to 66 Mohm and capacitance to 66 mF. With the auto power off feature you won’t have to worry about accidental battery consumption. Value-packed features make this meter a must in every “Tool Kit®”.
Multimeters Template | |
|---|---|
| Style | Hand-Held |
| Measures AC V | Yes |
| Measures DC V | Yes |
| Measures AC A | Yes |
| Measures DC A | Yes |
| True RMS | Yes |
| Maximum Voltage AC | 750 V |
| Resolution AC Volts | 1 V (1000 mV) |
| Maximum Voltage DC | 1000 V |
| Resolution DC Volts | 1 V (1000 mV) |
| Maximum Current AC | 10 A |
| Minimum Current AC | 660 uA (0.66 mA) |
| Resolution AC Current | 10 mA |
| Maximum Current DC | 10 A |
| Minimum Current DC | 660 uA (0.66 mA) |
| Resolution DC Current | 10 mA |
| # Digit Display | 3.75 |
| Counts | 6600 . |
| Backlight | Yes |
| Manual/Autoranging | Both |
| Decibels | No |
| Resistance | Yes |
| Frequency | Yes |
| Capacitance | Yes Capacitance to 66,000 uF |
| Temperature | No |
| Diode Testing | Yes |
| CAT Rating | III CAT Rating CATII 1000V, CATIII 600V |
| CAT Voltage | 1,000 V CAT Voltage CATII 1000V, CATIII 600V |
| Intrinsically Safe | No |
| Peak Hold | No |
| Overload Protector | Yes |
| Kelvin 4-Wire Measurement Capability | No |
| Wireless Display | No |
Product General Attributes | |
| Warranty | 3 YEARS |
| Product Weight | 0.62 LBS |
| Product Height | 165 MM (6.50 IN) |
| Product Length | 43 MM (1.69 IN) |
| Product Width | 78 MM (3.07 IN) |
| HTS/Schedule B Number | 9030.31.0000 |
| ECCN Number | EAR99 |
| Country of Origin | Taiwan |
| Other Information | Ranges: 660 mV, 6.6 V, 66 V, 660 V, 1000 V Resolution: 0.1 mV, 1 mV, 10 mV, 100 mV, 1 V Accuracy: ?(0.5 % rdg + 2 dgts) Input Impedance: 660 mV: 100 MO 6.6 V: 10 MO 66 V to 1000 V: 9.1 MO Overload Protection: 1000 VDC or 750 VACrms Ranges: 660 mv, 6.6 V, 66 V, 660 V, 750 V Resolution: 0.1 mV, 1 mV, 10 mV, 100 mV, 1 V Accuracy: 660 mV range at 50 Hz to 60 Hz ?(1.5 % rdg + 8 dgts) 6.6 V to 660 V ranges: ?(1.5 % rdg + 8 dgts) 750 V range: ?(2.0 % rdg + 8 dgts) Input Impedance: 660 mV: 100 MO 6.6 V: 10 MO 66 V to 750 V: 9.1 MO Overload Protection: 1000 VDC or 750 VACrms* Ranges: 660 uA, 6600 uA, 66 mA, 400 mA, 10 A Resolution: 0.1 uA, 1 uA, 10 uA, 100 uA, 10 mA Accuracy: 660 uA to 400 mA ranges: ?(1.5 % rdg + 2 dgts) 10 A range: ?(3.0 % rdg + 3 dgts) Input Protection: 0.5 A/500 V & 10 A/600 V fast blow ceramic fuses Ranges: 660 uA, 6600 uA, 66 mA, 400 mA, 10 A Resolution: 0.1 uA, 1 uA, 10 uA, 100 uA, 10 mA Accuracy: 660 uA to 400 mA ranges: ?(2.0 % rdg + 10 dgts) 10 A range: ?(3.5 % rdg + 10 dgts) Input Protection: 0.5 A/500 V & 10 A/600 V fast blow ceramic fuses Ranges: 660 O, 6.6 kO, 660 kO, 6.6 MO, 66 MO Resolution: 0.1 O, 1.0 O, 10 O, 1 kO, 10 kO Accuracy: 660 O to 660 kO ranges: ?(1.2 % rdg + 5 dgts) 6.6 MO range: ?(2.0 % rdg + 5 dgts) 66 MO range: ?(3.5 % rdg + 5 dgts) Open Circuit Voltage (typical): -0.45 VDC (-1.2 VDC on 660 O range) Overload Protection: 500 VDC/ACrms Ranges: 6.6 nF , 66 nF, 660 nF, 6.6 uF, 66 uF, 660 uF, 6.6 mF, 66 mF Resolution: 1 pF, 10 pF, 100 pF, 1 nF, 10 nF, 100 nF, 1 uF, 10 uF Accuracy: 6.6 nF range: ?(3.0 % rdg + 30 dgts) 66 nF to 660 uF ranges: ?(3.0 % rdg + 5 dgts) 6.6 mF to 66 mF ranges: ?(5.0 % rdg + 20 dgts) Overload Protection: 500 VDC/ACrms Ranges: 660 Hz, 6.6 kHz, 66 kHz, 660 kHz, 6.6 MHz, 66 MHz Resolution: 0.1 Hz, 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz Accuracy: ?(0.1 % rdg + 3 dgts) Sensitivity: 10 Hz to 6.6 MHz: 2.5 Vrms, 6.6 MHz to 66 MHz: 2.5 Vrms 5 Vrms Overload Protection: 500 VDC/AC rms Test Current: 1.2 mA (typical) Resolution: 1 mV Accuracy: ?(1.5 % rdg + 3 dgts) Open Circuit Voltage: 3.5 VDC (typical) Overload Protection: 500 VDC/ACrms Audible Indication: Less than 30 O Response Time: 100 ms Overload Protection: 500 VDC/ACrms |