Description
Instek APS-7050E – 500VA Linear A.C. Power Source

- 4.3 inch TFT-LCD Display
- Output Capacity: APS-7050E(500VA, 310Vrms, 4.2/ 2.1Arms), APS-7100E(1000VA, 310Vrms, 8.4/ 4.2Arms)
- Measurement function comprises Voltage, Current, Power, Current(peak), Frequency, Power Factor
- Frequency: 45.0 ~ 500.0Hz(Std); 45.0 ~ 999.9Hz(opt)
- Voltage Range(RMS) : 155V(Std)/600V(opt)
- OVP/OCP/OTP Protection
GW Instek launches the APS-7000E series the economy version of the APS-7000 programmable AC power source. With the height of 2U, the maximum rated output for APS-7050E is 500VA, 310Vrms, 4.2Arms and APS-7100E is 1000VA, 310Vrms, 8.4Arms. The output frequency range of the series is 45~500Hz. The series is ideal for the test and development of DC power supply devices, consumer electronics, automotive electronics and electronic components.
The APS-7000E series comprises six measurement and test functions (Vrms, Irms, F, Ipk, W, PF), and provides user interface similar to that of AC Power Meter. The APS-7000E series, via switching many sets of current levels to increase small current measurement resolution, is ideal for the LED industry and standby mode power consumption test. Ten sets of Preset allow users to store ten settings.
To meet the test criteria of line voltage fluctuation often seen in consumer electronics, the APS-7000E series not only provides a stable AC power source but also features the Test mode to satisfy special or abnormal voltage and frequency variation demands. Ten sets of the Test mode simulate power outage, voltage rise, and voltage fall. The APS-7000E series that simulates waveforms of city power grid’s transient changes is suitable for verifying electronics products operated under abnormal power source.
The APS-7000E series is the economy version of the APS-7000 series. If communications interface and larger voltage/frequency are required, please refer to the APS-7000 series. The functionality comparison between the APS-7000 series and the APS-7000E series is listed on this NPI.
APS-7050/7050E Output Operating Area
APS-7100/7100E Output Operating AreaA. SEQUENCE MODE
There are ten sets of Sequence mode and each set has 0~255 steps. The time setting range for each step is 0.01 ~ 99.99 seconds. Combining many sets of steps to edit required waveforms satisfies users’ requirement of highly complicated waveforms.
Sequence WaveformB. PROGRAM MODE
This mode allows users to set ceiling and floor specifications to produce PASS/FAIL result after the measurement is done. It can also show test results for each test procedure or only show the last result. There are ten sets of Program mode and each set has 50 sets of memories. Each memory comprises 9 steps. Each Program will perform according to memories sequence, self-defined loops or designated steps to stop.
Program ModeC. SIMULATE MODE
This mode can rapidly produce different simulated input transient waveforms such as power outage; voltage rise and voltage fall etc. for engineers to evaluate the impact on DUT posed by the transient phenomena. For instance, capacitor endurance test.
Power Outage
Voltage Rise
Voltage FallD. ARB MODE
This mode provides more than 50 different waveforms in 7 major categories to rapidly simulate distorted AC voltage waveforms.

Sine waveform
Standard AC Waveform

Triangle waveform
Power harmonic output simulation is triangle waveform

Staircase waveform
Simulate square waveform and staircase waveform for commercial UPS

Clipped sinewave
Simulate grid power supply heavy load waveform

Crest factor waveform
Simulate rectified filter current waveform by capacitor input

Surge waveform
Simulate grid power supply’s peak over-voltage

Fourier series synthesized waveform
Simulate real output power waveform. Distorted power waveform is produced due to output impedance and non-linear effect such as inductance, capacitance, and parasitic capacitance effect. For example: motor.
E. RAMP CONTROL
Ramp control allows users to set output voltage rise or fall speed which is based on time (1ms) or voltage (1Vrms) unit.
Tup-> 0.1 ~ 999.9msTdn-> 0.1 ~ 999.9ms
Vup-> 0.01 ~ 99.99 VrmsVdn-> 0.01 ~ 99.99 Vrms
Mode=Time, Tup=1 msec, VAC=100V, Freq=50Hz, Ramp output=on.
Mode=Voltage, Vdn=2Vrms, VAC=100V, Freq=50Hz, Ramp output=off.F. SURGE/DIP CONTROL
Dip
SurgeG. T IPEAK, HOLD FUNCTION
T, Ipk Hold sets delay time (1ms~60 seconds) for measurement after the output of Ipeak value and the maximum value will be retrieved. Update will be preceded only if measured value is greater than the original value. Ipk Hold is for measuring transient inrush current as soon as the equipment power is on that is usually done by oscilloscope and current probe. T, Ipk Hold delay time setting can be applied to measure inrush current of sequentially activated DUT.
Ipeak MeasurementH. CONTROL PANEL CHARACTERISTICS
There are two control panel modes: Standard mode and Simple mode. Both modes are shown as below. Standard mode combines settings and AC Power Meter measurement window display. Users apply Function key (F1~F3) to select required measurement items. There are nine items for selection. Simple mode shows all measurement items on the display.
Standard Mode
Simple ModePANEL INTRODUCTION


- AC Power Switch
- Universal Regional Plug
- USB A Port
- Display 4.3 inch TFT
- Function Keys
- Scroll Wheel
- Line Voltage Input
- Ethernet Port
- Remote Control -J1 Connector
- Signal Output Connector
- Synch Output
- GPIB
- Rear Panel Output Terminal
Power Supplies/AC Power Supplies Template | |
|---|---|
| Output Capacity | 500 VA (500 Watts) |
| Meter Type | Digital |
| Variable Frequency | Yes |
| Programmable | Yes |
| Linear/Switching | Linear |
| Outputs | Single |
| Voltage Output 1 | Variable |
| Max Voltage Output 1 | 310 V |
| Current Output 1 | Variable |
| Max Current Output 1 | 4.2 A |
| Output Adaptor Plug | European, Multi Output Adaptor Plug Universal AC output Socket |
| Max Display Resolution Current | 0.01 mA (0.00001 A) |
| Max Display Resolution Voltage | 0.01 V (10 mV) |
| Constant current/voltage | Yes |
Product General Attributes | |
| Unique Features | AC Power measurement function Vrms, Irms, F, Ipk, W, PF with similar accuracy of AC Power meter Test Mode |
| Warranty | 2 YEARS |
| Safety Approval | CE |
| Storage | Internal Memory, USB Flash Drive |
| Product Weight | 24 LBS |
| Product Height | 88 MM (3.46 IN) |
| Product Length | 400 MM (15.75 IN) |
| Product Width | 430 MM (16.93 IN) |
| Data Logging | Yes |
| HTS/Schedule B Number | 8504.40.9510 |
| ECCN Number | 3A992 |
| Calibration Included | Factory Calibration |
| Country of Origin | Taiwan |





Reviews
There are no reviews yet.