B&K Precision HVL800150 – High Voltage DC Electronic Load (800 V, 150 A, 6 kW)

Please, activate Wishlist option to use this widget.
Please, activate Compare option to use this widget.
32 people are viewing this product right now

$15,730.00

Shipping calculated at checkout.
or
Add to quote
Estimated delivery:5 days

High Voltage DC Electronic Load (800 V, 150 A, 6 kW)

  • 800 V, 150 A, 6 kW High Voltage DC Electronic Load
  • CC/CV/CR/CW operating modes
  • Continuous, pulse, and toggle transient operation
  • Transient mode speed up to 10 kHz in CC mode
  • Adjustable loop response speed
  • Adjustable voltage and current slew rates
  • OVP, OCP, OPP, reverse voltage, and key-lock protections
  • Oscillation protection
  • USB (USBTMC-compliant), LAN, RS232, and GPIB interfaces standard
  • LabVIEW drivers provided
SKU: B&K Precision HVL800150 EAN: 817050911251 Tags: , Categories:
Pay safely with Visa Pay safely with Master Card Pay safely with PayPal Pay safely with Maestro Tooltip text
Guarantee Safe and Secure Payment Checkout

Description

B&K Precision HVL800150

  • CC/CV/CR/CW operating modes
  • Continuous, pulse, and toggle transient operation
  • Transient mode speed up to 10 kHz in CC mode
  • Advanced list mode programming
  • Adjustable loop response speed

High Voltage DC Electronic Load (800 V, 150 A, 6 kW)

The HVL Series DC Electronic Loads offer a wide operating voltage up to 1000 V and high-power density providing 6 kW in a 5U form factor. In addition to CC/CV/CR/CW operating modes, the HVL Series features continuous, pulse, and toggle transient operation. Up to 10 identical HVL Series models can be combined in parallel to increase total sink capabilities to 60 kW.

Suitable for ATE system applications, this series supports a variety of dynamic loading conditions for evaluating DC-DC converters, batteries, battery chargers, photovoltaic arrays, and other high-power DC sources.

Several Versions Available

The HVL Series DC electronic loads are offered in multiple output configurations to suit a variety of testing conditions. Note the different form factor for the higher-current products.

ModelHVL600150HVL80075HVL100025HVL600300HVL800150HVL100050
Power3 kW3 kW3 kW6 kW6 kW6 kW
Rated Voltage600 V800 V1000 V600 V800 V1000 V
Rated Current150 A75 A25 A300 A150 A50 A
Form Factor3U3U3U5U5U5U

List Mode

Each list mode program contains up to 100 user-programmable steps. Save up to 10 list mode programs directly to internal memory for quick recall. Step parameters include current limit, step duration, and slew rate. List mode programs can be set to repeat a maximum of 100,000 times. BOST / EOST (Beginning / End of step Trigger) can be enabled for any step in the list to generate output triggers for synchronizing events with other externally connected instruments. List mode programs can be configured and run from the front panel or remotely using the provided application software.

Parallel Operation

For applications requiring more power, up to 10 identical HVL Series DC load models can be connected in parallel to increase the maximum sink power to 60 kW. Once configured, the connected units will display the voltage and current of the complete system.

Transient Operation

Transient operation enables the DC load to periodically switch between two load levels.

Transient – Continuous

Switch continuously between A and B load current levels where rise/fall slew rates and level width can be adjusted.

Transient – Pulse

Upon enabling the input, the load executes one pulse cycle returning to Level-A and waits to receive a trigger signal before executing another pulse.

Transient – Toggle

The DC load current will switch between Level-A and Level-B following receipt of a trigger signal.

Application Software

  • PC software is provided for generating and executing test sequences and measurement data logging without the need to write source code
  • Log voltage, current, power measurements, and export data in spreadsheet format for further analysis
  • Configure and run transient operation, list mode, and more

Low Voltage Operation

The HVL Series can operate at low voltages for applications in fuel cell and solar cell testing.

Minimum Operating Voltages

HVL600150 = 3.5 V

HVL80075 = 2.0 V

HVL100025 = 3.5 V

HVL600300 = 3.5 V

HVL800150 = 2.0 V

HVL100050 = 3.5 V

Power Supplies/Electronic Loads Template

Watts6 kW (6000 Watts)
Max Current150 A
Max Voltage800 V
Min Current0 A
Min Voltage0 V
ProgramableYes
TriggeringYes
Battery TestYes
Remote SensingYes

Product General Attributes

Warranty3 YEARS
Safety ApprovalCSA, UL
Interfaces I/O GPIB, LAN / Ethernet, RS-232, USB
StorageUSB Flash Drive
Data LoggingYes
Calibration IncludedFactory Calibration
Power Supply Voltage120V 50/60 Hz

Reviews

There are no reviews yet.

Be the first to review “B&K Precision HVL800150 – High Voltage DC Electronic Load (800 V, 150 A, 6 kW)”

Manuals/Guides

B&K Precision HVL800150 &...

$15,730.00

Our team of knowledgeable professionals is here to help you make informed decisions. Whether you need product recommendations, technical support, or guidance on your purchase, we're just a click away.

Contact Us Now:
📧 sales@nestesinstruments.com
📞 +1 (833) 763-7837


Let us assist you in finding the perfect solution!
Have Questions? Ask an Expert!