Keysight E9326A – Peak/Average Power Sensor (50 MHz – 18 GHz; 1.5 MHz Video Bandwidth)

Brand:
Please, activate Wishlist option to use this widget.
Please, activate Compare option to use this widget.
18 people are viewing this product right now
Shipping calculated at checkout.
or
Add to quote
Estimated delivery:3 days

Peak and Average Power Sensor, 50 MHz to 18 GHz, 1.5 MHz Bandwidth

  • Peak and average power sensor
  • Frequency range: 50 MHz to 18 GHz
  • Video bandwidth: 1.5 MHz
  • Ideal for time-gated peak, average, and peak-to-average ratio power measurements on TDMA and CDMA wireless formats such as Bluetooth
  • Fast measurement speed, up to 1000 corrected readings per second, via the GPIB
  • Operates with the EPM-P (E4416A/ 17A) series and P-Series (N1911A/ 12A) power meters
  • Calibration factors, linearity, temperature, and bandwidth correction stored in EEPROM
  • Precision type-N connector as standard
SKU: Keysight E9326A Tags: , , , Categories:
Pay safely with Visa Pay safely with Master Card Pay safely with PayPal Pay safely with Maestro Tooltip text
Guarantee Safe and Secure Payment Checkout

Description

Keysight E9326A

  • Peak and average power sensor
  • Frequency range: 50 MHz to 18 GHz
  • Video bandwidth: 1.5 MHz
  • Ideal for time-gated peak, average, and peak-to-average ratio power measurements on TDMA and CDMA wireless formats such as Bluetooth

Peak/Average Power Sensor (50 MHz – 18 GHz; 1.5 MHz Video Bandwidth)

The E-Series E9320 power sensors have two frequency ranges. The E9325A, E9326A, and E9327A have a frequency range of 50 MHz to 18 GHz while the 50 MHz to 6 GHz range of the E9321A, E9322A, and E9323A covers most wireless communication applications.

Sensor Specification

Sensor ModelVideo BandwidthFrequency Range Maximum PowerConnector Type

E9321A

E9325A

300 kHz

50 MHz to 6 GHz

50 MHz to 18 GHz

+23 dBm average;

+30 dBm peak

(< 10 µsec duration)

Type N (m)

E9322A

E9326A

1.5 MHz

50 MHz to 6 GHz

50 MHz to 18 GHz

+23 dBm average;

+30 dBm peak

(< 10 µsec duration)

Type N (m)

E9323A

E9327A

5 MHz

50 MHz to 6 GHz

50 MHz to 18 GHz

+23 dBm average;

+30 dBm peak

(< 10 µsec duration)

Type N (m)

  • E9321A and E9325A sensors with 300 kHz bandwidth are suitable for measuring TDMA signals such as GSM
  • E9322A and E9326A sensors with 1.5 MHz bandwidth are suitable for measuring IS-95 CDMA signals
  • E9323A and E9327A sensors with 5 MHz bandwidth are suitable for measuring W-CDMA signals

Measurement Ranges

The E9320 power sensors have two measurement ranges (lower and upper).

         E9321A/E9325A         E9322A/E9326A         E9323A/E9327A

NormalAverage only
NormalAverage only
NormalAverage only
Lower range (min. power)
-50 dBm-65 dBm
-45 dBm-60 dBm
-40 dBm-60 dBm
Lower range (max. power)
Lower to upper auto range point
+0.5 dBm-17.5 dBm¹
-5 dBm-13.5 dBm²
-5 dBm-10.5 dBm²
Upper to lower auto range point
-9.5 dBm-18.5 dBm
-15 dBm-14.5 dBm
-15 dBm-11.5 dBm
Upper range (min. power)
-35 dBm-50 dBm 
-35 dBm-45 dBm
-30 dBm-35 dBm
Upper range (max. power)
+20 dBm+20 dBm¹ 
+20 dBm+20 dBm²
+20 dBm+20 dBm²

1 For average power measurements, free run acquisition.

2 Applies to CW and constant amplitude signals only above -20 dBm.

Use the default normal path for continuously sampled measurements of modulated signals and time-gated measurements. For each frequency range, there is a choice of sensors with three videos (modulation) bandwidths.

Note, however, that the sensors with the widest bandwidth have the smallest dynamic range (in normal mode). If the dynamic range is an important factor, use the sensor model with just enough video bandwidth for the measurement you want to make.

The average-only path is suitable for average power measurements of Continuous Wave (CW) and constant amplitude signals between –65 dBm (sensor dependent) and +20 dBm. The average-only path can also be used to measure the true average power of any complex modulated signal below –20 dBm.

Calibration factors, linearity, temperature, and bandwidth compensation data are stored in the sensor EEPROM during the manufacturing process. All the compensation data is downloaded to the EPM-P Series power meter at power-on or when the sensor is connected. You only need to enter the frequency of the RF signal you are measuring to achieve a high degree of accuracy.

RF and Microwave Power Sensors Template

LAN versionNo
Minimum Frequency (RF Power Sensors)50 MHz
Maximum Frequency (RF Power Sensors)18 GHz
Sensor TechnologyDiode

Reviews

There are no reviews yet.

Be the first to review “Keysight E9326A – Peak/Average Power Sensor (50 MHz – 18 GHz; 1.5 MHz Video Bandwidth)”
Keysight E9326A – Peak/A...

$5,143.60

Our team of knowledgeable professionals is here to help you make informed decisions. Whether you need product recommendations, technical support, or guidance on your purchase, we're just a click away.

Contact Us Now:
📧 sales@nestesinstruments.com
📞 +1 (833) 763-7837


Let us assist you in finding the perfect solution!
Have Questions? Ask an Expert!