Compliance West HT-10KVPac/dc Hipot Tester, 0-10KVac @ 10mA / 0-14KVdc @ 5 mA

Please, activate Wishlist option to use this widget.
Please, activate Compare option to use this widget.
11 people are viewing this product right now

Original price was: $5,379.00.Current price is: $5,239.28.

Shipping calculated at checkout.
or
Add to quote
Estimated delivery:5 days

Hipot Tester, 0-10KVac @ 10mA / 0-14KVdc @ 5 mA

  • AC output: up to 10,000 V
  • DC output: up to 14,000 V
  • Microcontroller Technology, one button test, easy to setup, LED’s indicate test progress. Upon failure, buzzer sounds and testing is terminated
  • Output voltage, leakage current limit, voltage ramp-up time and test duration are controlled from the front panel
  • Voltage ramp, arc detection and test timer are defeatable
  • Separate arc detection circuitry
  • Ergonomically designed for safety, speed and efficiency
  • Designed for product development and laboratory use
  • Cables, manual and calibration certificate included
  • One year calibration cycle
  • One year warranty
SKU: Compliance West HT-10KVPac/dc Tags: , Categories:
Pay safely with Visa Pay safely with Master Card Pay safely with PayPal Pay safely with Maestro Tooltip text
Guarantee Safe and Secure Payment Checkout

Description

Compliance West HT-10KVPac/dc – Hipot Tester, 0-10KVac @ 10mA / 0-14KVdc @ 5 mA

  • Model HT-10000P ac / dc is a 10,000V AC or 14000V DC Hipot Tester
  • Cables, manual and calibration certificate included
  • One year calibration cycle
  • One year warranty

The dielectric withstand test is a test which is recognized by safety agencies worldwide as a valid criterion of safe assembly of end-use equipment. The HT-10000P is designed as a research instrument to determine the dielectric properties of component assemblies of end-use equipment. It applies a high-voltage potential between Output and Return test leads and monitors Leakage Current and watches for Dielectric Breakdown during the test. To aid in testing, the HT-10000P can be configured with or without voltage ramp time, with or without a test duration timer, and can be set to deliver high voltage after an arc has been detected to pinpoint an area of arcing.

The dielectric withstand test involves high voltage and caution should be exercised when using the HT-10000P. The Return Receptacle on the front panel is connected to ground potential, and setups should be designed with this in mind, to guard against the operator contacting high voltage. Always make sure the return lead is firmly connected.
 

Leakage Test

 

The HT-10000P leakage test uses a separate low-frequency circuit to detect excessive current between the Output and Return receptacles on the front panel. There is not a specific leakage current level pass/fail requirement at this time for most equipment. However, higher than normal leakage current on a particular sample may indicate an assembly or component problem in the circuit.

The leakage current is also monitored by the HT-10000P to ensure that excessive leakage does not keep the tester from developing full voltage required for the high voltage test. The HT- 10000P will provide full voltage at any leakage current level up to 5mA in DC and 10mA in AC. Set the acceptable leakage current limit using the Shutdown Limit Potentiometer on the front panel. The Shutdown Limit Switch must be set to ON or the HT-10000P keep testing regardless of Leakage Current. Voltage output may sag under these conditions.

If the green Full Voltage indicator lights and the test continues, the leakage current was below the acceptable limit. If the red Excess Leakage indicator lights, the buzzer sounds, and the test is terminated; the leakage current was above the acceptable limit.
 

High Voltage Dielectric Withstand Test

 

This test checks for insulation system breakdowns by applying a high voltage between the Output and Return receptacles on the front panel. The HT-10000P uses a separate high- frequency circuit to detect arc breakdowns.

Set the test duration with the Timer Control Potentiometer on the front panel. The test time is counted from the time the Full Voltage indicator is lit to the completion of the test. The Timer Control Switch must be set to ON or the HT-10000P will test only while the Test Button is pressed. The minimum test time is one second regardless of the setting of the Timer Control Switch.

If the green Hipot Pass indicator lights, the test cycle has been successfully completed, meaning there was no dielectric breakdown. If the red Hipot Fail indicator lights, a breakdown arc has been detected.
 

High Voltage Discharge

 

The HT-10000P has an internal ramp down circuit designed to discharge the high voltage after completion of the dielectric withstand test. The HT-10000P should remain connected to the circuit until the front panel meter shows that the output voltage has dropped to a safe level.

Safety Testing / Surge Testing/Hipot Tester Template

Test Type HipotAC, DC
Max AC Test Voltage10000 V (10 kV)
Max DC Test Voltage14000 V (14 kV)
Min AC Test Voltage0 V
Min DC Test Voltage0 V
Max Trip Current AC Test10 mA
Min Trip Current AC Test1 mA 
Max Trip Current DC Test5 mA
Min Trip Current DC Test1 mA 
Programmable (hipot)Yes
Ground Continuity Current AC47 mA (0.047 A)
Arc DetectionYes

Product General Attributes

Warranty1 MONTHS (0.083 YEARS)
Interfaces I/O Analog Output, Analog Input
Product Weight20 LBS 
Product Height4 IN
Product Length12 IN 
Product Width11 IN
Calibration IncludedFactory Calibration
Shipping Height10.00 IN
Shipping Length21.00 IN
Shipping Width21.00 IN
Other Information

HT-10kVac: to 10,000Volts ac. Leakage current 1 – 10mA AC.

HT-10kVdc: to 14,000Volts dc. Leakage current 1 – 5mA DC.

HT-10kvac/dc: combines outputs and adds a current meter to the front panel. 3U enclosure.

 : Current capabilities of 25, 100 and 500mA available. Consult factory.

Leakage Current: Adjustable via knob to any intermediate setting.

Arc Detection: Separate high frequency detection circuit for breakdown spike detection.

Test Time: 1-60 sec., defeatable for operation while button is pressed.

Voltage Ramp Time: .5-5 seconds, defeatable.

Leakage Fail Point: AC – 1 – 10mA DC – 1-5mA via knob.

Voltage Ramp Defeat: applies voltage without ramp.

Timer Duration Defeat: applies voltage only while TEST button is pressed.

Shutdown on Failure Defeat: disables Arc Detection circuit.

Voltage rampdown time: AC – .5 sec max; DC – 8 sec max.

Duty Cycle: 100%

Meter accuracy: ?3% 500-10kV

Reviews

There are no reviews yet.

Be the first to review “Compliance West HT-10KVPac/dc Hipot Tester, 0-10KVac @ 10mA / 0-14KVdc @ 5 mA”
Weight20 lbs
Dimensions12 × 11 × 4 in
Compliance West HT-10KVPac/dc ...

Original price was: $5,379.00.Current price is: $5,239.28.

Our team of knowledgeable professionals is here to help you make informed decisions. Whether you need product recommendations, technical support, or guidance on your purchase, we're just a click away.

Contact Us Now:
📧 sales@nestesinstruments.com
📞 +1 (833) 763-7837


Let us assist you in finding the perfect solution!
Have Questions? Ask an Expert!