Description
Compliance West HT-3000P AC 1A V2 Hipot Tester, 3000Vac @ 1A Max Continuous Duty, No Ramp, No Arc Detection

- AC output: up to 3,000 V
- Leakage current up to 1000mA
- Main shutdown switch on front panel for safety
- Leakage current cutoff can be set from 30mA to 1000mA
- Zero voltage start included
- One year calibration cycle
- One year warranty
HT-3000PAC-1A V2 is an AC only hipot tester with an output up to 3000V and leakage current up to 1A. Not only powerful but safe, the main shutdown switch is strategically located on the front panel. 1A max continuous duty, no ramp, no arc detection. Advanced micro-controller technology allows for easy 1-button testing. Made in the USA. Calibration certificate and 1yr warranty included.

Controls, Indicators, Connectors – HT-3000P-1A-AC Front Panel
| NO. | NAME | FUNCTION |
| 1. | AC Power switch | Turns On (I) or Off (O) the tester. |
| 2. | Fuse | Use only 1A 250V replacement fuse slow blow. |
| 3. | Leakage Limit Adjustment knob | Used to adjust the trip level for the excessive leakage current test. |
| 4. | Timer switch | When switch is in Defeat, the test duration will be the time the test switch is pressed +1 second. In the On position the test time will depend on the time adjust potentiometer 1-60 seconds. |
| 5. | Test Time Adjust knob | Adjust the test time from 1 – 60 seconds. |
| 6. | RESET Button / Red Indicator | When lit, indicates that the HT-3000P-1A-AC is unarmed. This button must be pushed before the test button is functional. When the reset button is pressed, the red reset indicator goes out and the yellow test indicator is lit. PRESSING THE RESET BUTTON AT ANY TIME STOPS THE TEST. |
| 7. | TEST Button / Blue Indicator | When lit, indicates that the HT-3000P-1A-AC is ready to test the connected equipment. The blue test indicator goes out when the test button is pressed. |
| 8. | Voltage Meter | Provides visual indication to the operator of the actual output voltage. |
| 9. | Hipot Pass LED | At the end of the test, if no Excess leakage was detected, the green hipot pass led will light and the test will terminate. |
| 10. | Full Voltage LED | Full voltage led indicates the test has started, the voltage is at the output and the duration timer starts. |
| 11. | Excess Leakage LED | Indicates failure of leakage current test. If leakage current between the primary circuit and ground is higher than the preset value, the red excess leakage led will light, the internal buzzer will sound, and the test will be terminated. |
| 12. | Hipot Fail LED | Indicates a failure when a high intensity ARC is detected. |
| 13. | Current Meter | Provides visual indication to the operator of the actual output current. |
| 14. | HV Output | Voltage will be present during test. The Red 18 AWG Test Lead provided will be connected. |
| 15. | Return Lead Receptacle | Grounded banana plug receptacle. The Green 10 AWG Test Return Lead provided will be connected |
| 16. | Voltage adjust knob | The test can only start if the knob is at the minimum. Once the test is running increase the voltage by turning the knob |
Safety Testing / Surge Testing/Hipot Tester Template | |
|---|---|
| Test Type Hipot | AC |
| Max AC Test Voltage | 3000 V (3 kV) |
| Max Trip Current AC Test | 1000 mA |
Product General Attributes | |
| Warranty | 1 YEARS |
| Product Weight | 160 LBS |
| Product Height | 40.00 IN |
| Product Length | 31.00 IN |
| Product Width | 31.00 IN |
| Power Supply Voltage | 240V Only |
| Shipping Height | 40.00 IN |
| Shipping Length | 31.00 IN |
| Shipping Width | 31.00 IN |