Description

Accuris AutoMATE 96
- Fast and accurate 96-channel pipetting
- Accepts 96/384 well microplates, PCR plates and reservoirs
- Touch screen tablet for programming and operation
- 4-position motorized platform
- Exchangeable pipette heads (1-20µL, 5-200µL, 100-1000µL) *sold separately*
Automated Microplate Pipetting Workstation
The Accuris AutoMATE 96 is a fully automated, high throughput liquid handling workstation that improves productivity when filling microplates. Capable of dispensing up to 96 channels simultaneously, the AutoMATE 96 significantly reduces the processing time and errors associated with manual pipetting.
The included tablet features an intuitive app for programming and operation. Unlike many 96-well pipetting stations, the AutoMATE 96 is “hands-free” with motorized tip loading & ejection and a four position, automated, sliding platform that precisely aligns the tips with the appropriate microplate/reservoir. Once programmed, the instrument can run protocols to completion without any manual positioning or adjustment.
Interchangeable Pipetting Heads
Interchangeable heads are sold separately and allow for a pipetting range from 1.0µL to 1000µL.
Part Number | Range | Accuracy | Precision |
MP9600-20PH | 1 – 20µL | ≤±12 % at 1μL ≤±1 % at 20μL | ≤10 % at 1μL ≤0.8 % at 20μL |
MP9600-200PH | 5 – 200µL | ≤±5 % at 5μL ≤±1 % at 200μL | ≤3.5 % at 5μL ≤0.4 % at 200μL |
MP9600-1000PH | 100 – 1000µL | ≤2.5 % at 100μL ≤1 % at 1000μL | ≤1.25 % at 100μL ≤0.4 % at 1000μL |
Pipette Tips
A full range of pipette tips are available (sold separately):
MP96-T20-LR | Racked 96 well, 20ul low retention, 24/cs |
MP96-T20-LRFS | Sterile, racked 96 well, 20ul filtered, low retention, 24/cs |
MP96-T200-LR | Racked 96 well, 200ul low retention, 24/cs |
MP96-T200-LRFS | Sterile, racked 96 well, 200ul filtered, low retention, 24/cs |
MP96-T1000-LR | Racked 96 well, 1000ul low retention, 16/cs |
MP96-T1000-LRFS | Sterile, racked 96 well, 1000ul filtered, low retention, 16/cs |
Pipetting Modes
Standard Pipetting: Aspirating and dispensing reagents by hand is labor-intensive and error prone. With AutoMATE 96, reagents can be aspirated and dispensed automatically, ensuring accurate and precise transfer to and from microplates or reservoirs.
Multi-Dispensing (Repeat Pipetting): Continually filling microplates is a time-consuming process that can often result in hand fatigue. With the multi-dispensing function, repeatedly filling microplates can be automated and accomplished quickly without introducing hand strain or fatigue.
Secondary-Dispensing (Plate Filling): Many protocols and applications call for filling a plate with multiple samples or reagents. With AutoMATE 96, multiple reagents can be aspirated and dispensed into the same microplate. For improved results, each dispense can be programmed to include a mixing step.
Serial Dilutions: Performing serial dilutions via manual methods is labor-intensive and error prone. Errors in this process will amplify subsequent dilutions as the process continues. With AutoMATE 96, serial dilutions can be performed automatically and error-free.
Mixing: Mixing reagents by hand is strenuous and can be inconsistent. With the AutoMATE 96, mixing can be performed automatically with adjustable speeds, ensuring consistency.
Reverse Pipetting: When the accuracy of pipetting volume is critical, AutoMATE 96 can be set to reverse pipetting mode. This technique greatly improves accuracy &precision with small volumes of biological fluids.
Software and Programming
There are two operating modes that can be user-selected, manual and automated program mode.
Manual Mode: Perform operations quickly and efficiently simply by selecting each function individually.
Manual Functions
- Load tips
- Eject tips
- Aspirate reagents
- Dispense reagents
- Mix reagents
- Blow out reagents

Automated Program Mode: Create a protocol made up of multiple steps in succession. This interface allows for complex protocols to be run from tip-loading through completion with the touch of a button.

Programmable Steps
- Load/Eject Tips
- Aspirate/Dispense reagents
- Perform serial dilutions
- Rinse tips
- Repeat a cycle
- Pause after a certain step
Broad Labware Compatibility
All brands of microplates and reservoirs meeting SLAS/ANSI formats are compatible for use with the AutoMATE 96. The included plate adapters allow 384 well microplates and PCR plates to be used.

PCR Plate Adapter

Well Plate Adapter
Applications
- PCR/qPCR setup in PCR plates
- Cell culture prep, media change
- Reagent addition
- Replication of microplates
- 384 well plate set up (special adapter included)
- Preparation of cell-based assays
- ELISA preparation (plate coating, washing, aspirating, master mix preparation)
Pipettes | |
---|---|
Type (Pipettes) | Automated (Robotic) |
# Channels (Pipettes) | 96 |
Volume Setting (Pipettes) | Variable |
Volume Min Pipettes (µL) | 1 Volume Min Pipettes (µL) dependent on head used |
Volume Max Pipettes (µL) | 1000 Volume Max Pipettes (µL) dependent on head used |
Special Features (Pipettes) | Multi dispensing (same volume) Special Features (Pipettes) 8-inch touchscreen tablet display, |
Product General Attributes | |
Interfaces I/O | USB |
Product Weight | 71.9 LBS |
Product Height | 26.5 IN |
Product Length | 27 IN |
Product Width | 13.8 IN |
Shipping Weight | 90 LBS |
Reviews