Description
Amprobe 35XP-A – Digital Multimeter with Temperature

- Temperature measurement capability to 1000 °C/1832 °F (type-K thermocouple included)
- 600 V AC/600 V DC – highest voltage rating in this class of meter
- Capacitance for motor run/start test
- 0.1 μA resolution for flame sensor testing
- Frequency to 1 MHz
- Resistance to 40 MΩ
The compact 35XP-A Digital Multimeter offers all the right features for HVAC and plant maintenance. It measures temperature, plus capacitance for motor run/start test, and offers 0.1 µA resolution for flame sensor testing.
Multimeters Template | |
---|---|
Style | Hand-Held |
Measures AC V | Yes |
Measures DC V | Yes |
Measures AC A | Yes |
Measures DC A | Yes |
True RMS | No |
Maximum Voltage AC | 750 V |
Resolution AC Volts | 100 uV (0.1 mV) |
Maximum Voltage DC | 1000 V |
Maximum Current AC | 2 A |
Minimum Current AC | 0.1 uA (0.00010 mA) |
Resolution AC Current | 0.1 uA (0.00010 mA) |
Maximum Current DC | 2 A |
Basic Accuracy V DC | ± 0.5% rdg + 1D |
# Digit Display | 3.75 |
Counts | 3999 . |
Backlight | No |
Manual/Autoranging | Manual |
Decibels | No |
Resistance | Yes |
Frequency | Yes |
Capacitance | Yes |
Temperature | Yes |
Diode Testing | Yes |
CAT Rating | I CAT Rating attribute_type should be multi_select |
CAT Voltage | 1,000 V, 300 V |
Intrinsically Safe | No |
Peak Hold | No |
Overload Protector | Yes |
Kelvin 4-Wire Measurement Capability | No |
Wireless Display | No |
Data Hold | Yes |
Low-Pass Filter | No |
Duty Cycle % | 30% to 70% Duty Cycle % attribute_type should be Text |
Product General Attributes | |
Unique Features | 0.1µA Resolution for Flame Sensor Testing, VolTect Non-contact Voltage Detector |
Warranty | 1 YEARS |
Warranty Details | 1 Year from the Date of Purchase, This Warranty Does Not Cover Fuses, Disposable Batteries or Damage from Accident, Neglect, Misuse, Alteration, Contamination or Abnormal Conditions of Operation or Handling |
Additional Info/Comments | Carrying Case, Test Lead Kit |
Product Weight | 400 GRAMS (0.882 LBS) |
Product Height | 6.1 IN |
Product Length | 1.26 IN |
Product Width | 2.83 IN |
Data Logging | No |
HTS/Schedule B Number | 9030.31.0000 HTS/Schedule B Number Value not available |
ECCN Number | EAR99 ECCN Number Value not available |
Calibration Included | Factory Calibration |
Power Supply Voltage | Battery Powered Power Supply Voltage Battery Operated Device |
Country of Origin | Taiwan Country of Origin Value not available |
Shipping Height | 2.10 IN Shipping Height Value not available |
Shipping Length | 10.10 IN Shipping Length Value not available |
Shipping Width | 7.05 IN Shipping Width Value not available |
Other Information | Display: 3-3/4 digit liquid crystal display (LCD) with a maximum reading of 3999 Polarity: Automatic, positive implied, negative polarity indication Overrange: (OL) or (-OL) is displayed Zero: Automatic Low Battery Indication: The indicator is displayed when the battery voltage drops below the operating level Auto Power Off: Approx. 10 minutes Measurement Rate: 2 times per second, nominal Operating Environment: 0 ?C to 50 ?C at 70 % R.H. Storage Temperature: -20 ?C to 60 ?C, 0 to 80 % R.H. with battery removed from meter Accuracy: Stated accuracy at 23 ?C ? 5 ?C, 75 % relative humidity Temperature Coefficient: 0.1 x (specified accuracy) per ?C (0 ?C to 18 ?C, 28 C to 50 ?C) Altitude: 2000 m Power: Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22 Battery Life: 150 hours typical with carbon-zinc, 300 hours typical with alkaline Dimensions: (H x W x D) 155 mm x 72 mm x 32 mm Weight: Approx. 400 g including battery Warranty: One-year DC Volts Range: 400 mV, 4 V, 40 V, 400 V, 1000 V AC Volts (45 Hz to 500 Hz) Range: 400 mV (45 Hz to 100 Hz) AC Volts (45 Hz to 500 Hz) Range: 4 V, 40 V, 400 V, 750 V Voltage Resolution: 100 µV Input Impedance: 400 mV: 100 M? ; 4 V: 10 M? ; 40 V to 1000 V: 9.1 Mv Overload Protection: 1000 V dc or 750 V ac rms DC Current Range: 400 µA, 4000 µA, 40 mA, 400 mA ? (1.0 % rdg + 2 dgt) DC Current Range: 2 A ? (2.0 % rdg + 3 dgts) AC Current (45 Hz to 500 Hz) Range: 400 µA, 4000 µA, 40 mA, 400 mA ? (1.5 % rdg + 5 dgts) AC Current (45 Hz to 500 Hz) Range: 2 A ? (2.5 % rdg + 5 dgts) Current Resolution: 0.1 µA Input Protection: 2 A/1000 V fast blow ceramic fuse 6.3 mm x 32 mm on A input Burden Voltage: 500 mV max. (2 V max. on 4 mA, 400 mA ranges) Resistance: 400 ? , 4 k? , 40 k? , 400 k? , 4 M? ? (1.0 % rdg + 4 dgts) Resistance: 40 M? ? (2.0 % rdg + 5 dgts) Resistance Resolution: 100 m? Open Circuit Voltage: -0.45 V dc typical, (-1.2 V dc on 400 ? range) Overload Protection: 1000 V dc or 750 V ac rms Temperature: 400 ?C, 1000 ?C, 400 ?F, 1832 ?F Resolution: 0.1 ?C, 0.1 ?F Overload Protection: 1000 V dc or 750 V ac rms Frequency: Range4 k, 40 k, 400 k, 1 M Accuracy ? (0.1 % rdg + 3 dgts) Resolution: 1 Hz Sensitivity: 10 Hz to 1 MHz: 2.5 V rms Minimum Pulse Width: 25 ns Duty Cycle Limits: 30 % and 70 % Overload Protection: 1000 V dc or 750 V ac rms Audible Indication: Less than 25 ? Response Time: 100 ms Overload Protection: 1000 VDC or 750 VAC rms Test Current: Range 1.2 mA (approximate) Accuracy ? (1.5 % rdg + 3 dgts) Resolution: 1 mV Open Circuit Voltage: 3.0 dc typical Overload Protection: 1000 V dc or 750 V ac rms Non-Contact Voltage Indicator: Sense voltage 70 V to 600 V ac beeper chirps and big bright red LED comes on, works on all ranges |