GasAlertMicro 5 Series
Providing protection from up to five potential atmospheric hazards including oxygen, combustible and toxic gases, GasAlertMicro 5 is unparalleled in its versatility, capability and overall value. BW Technologies by Honeywell’s newest addition to its water-resistant line of portable gas detectors has transformed the market with its matchless array of features.
Continuously monitoring and displaying concentrations of up to five gases, the compact and lightweight GasAlertMicro 5 was designed and engineered with an extensive host of applications in mind.
Additional Features:
- Integral concussion-proof boot
- Optional integral motorized pump option for remote sampling
- Powered by three AA alkaline batteries or a hot-swappable rechargeable battery pack
- Triple alarms (audible, visual and vibrating)
- Multi-language support in English, French, German, Spanish and Portuguese
- Large, user selectable backlit LCD
- Four alarm levels: Low, High, TWA and STEL
- Compatible with MicroDock II Automatic Test and Calibration Station
- Datalogging models store and recall event information
- Wide range of user selectable field options including password protection, safe and stealth modes.
Self-Tests
- Full function self-test confirms sensor, battery and circuitry integrity and audible/visual alarms on activation
GasAlertMicro 5 IR M5-XWAY-R-P-D-Y-N-00
Compact and lightweight, simultaneously monitors up to five atmospheric hazards and alerts you I the event of low, high, TWA or STEL alarm condition.
GasAlertMicro 5 IR portable gas detector simultaneously monitors up to five atmospheric hazards including carbon dioxide (CO2), oxygen (O2), combustible gas (%LEL), and a wide selection of toxic gases. Compact and lightweight, GasAlertMicro 5 IR activates audible, visual and vibrating alarms in the event of a low, high, TWA or STEL alarm condition.
Features & Benefits
- Monitors CO2 (IR), H2S, CO, O2, SO2, NH3, O3 and combustibles
- 0-5% vol (0-50,000 ppm) measurements of carbon dioxide
- Simple automatic calibration procedure
GasAlertMicro 5 Display Elements
Legend | Service Parts | Part Number |
C | Replacement front enclosure (yellow) for GasAlertMicro 5 Series | M5-FC1 |
Replacement front enclosure (black) for GasAlertMicro 5 Series | M5-FC1B | |
F | Replacement back enclosure (yellow) with screws for GasAlertMicro 5 Series | M5-BC1 |
Replacement back enclosure (black) with screws for GasAlertMicro 5 Series | M5-BC1B | |
A | Replacement diffusion cover (yellow) for GasAlertMicro 5 Series | M5-DC-1 |
Replacement diffusion cover (black) for GasAlertMicro 5 Series | M5-DCB-1 | |
Replacement alligator-style clip with screw (stainless steel) | GA-AG-2 | |
Replacement battery latch | M5-BL-1 | |
D | Replacement main PCB for GasAlertMicro 5 Series | M5-DL2-MPCB3 |
E | Replacement sensor PCB for GasAlertMicro 5 | M5-SPCB3 |
Replacement sensor PCB for GasAlertMicro 5 PID | M5PID-SPCB3 | |
Replacement sensor PCB for GasAlertMicro 5 IR | M5IR-SPCB1 | |
L | Replacement nozzle for generation 2 GasAlertMicro 5 Series pump module (with filter window) | M5-PN-1 |
Hose assembly with syringe filter | M5-QCONN-K1 | |
J | Replacement battery latch for GasAlertMicro 5 Series | M5-BL-1 |
H | Replacement multimedia card for GasAlertMicro 5 Series | M5-MMC |
I | Replacement screw kit for GasAlertMicro 5 Series | M5-SCREW-K1 |
Replacement screwdriver and alkaline battery pack screws for GasAlertMicro 5 Series | M5-ALLEN |
- With detector OFF, use No. 1 Phillips screwdriver to remove 2 screws (G) from back enclosure (F) on either side of the belt clip
- Lift diffusion cover (A) or pump module straight up
- Remove sensor (O-R) by pulling straight up from PCB (E)
- Insert new sensor (O-R) into PCB (E)
- Replace diffusion cover (A) or pump module
- Replace 2 screws (G) in back enclosure (F) and hand-tighten until firm
- With detector OFF, use No. 1 Phillips screwdriver to remove 2 screws (G) from back enclosure (F) on either side of the belt clip
- Lift diffusion cover (A) or pump module straight up
- Remove sensor screen (B) by pulling it straight up from diffusion cover (A) or pump module
- Insert sensor screen (B) into diffusion cover (A) or pump module
- Replace diffusion cover (A) or pump module
- Replace 2 screws (G) in back enclosure (F) and hand-tighten until firm
Gas Detection/Personal Gas Detection Template | |
---|---|
Number of Gases | 5-gas |
Gas Types | CO, H2S, LEL, NH3, O2 |
Alarm (Personal Gas Detector) | Audible, Audible-Visible-Vibrating, Vibrating, Visual |
Type (Gas Detection) | Portable |
CO2 | No |
CO | Yes |
H2S | Yes |
SO2 | No |
O2 | Yes |
NO2 | No |
O3 | No |
Ph3 | No |
NH3 | Yes |
CL2 | No |
CLO2 | No |
LEL | Yes |
Min Measurement Range CO | 0 PPM Min Measurement Range CO unit_id & unit_name is Missing in Reference File |
Min Measurement Range H2S | 0 PPM Min Measurement Range H2S unit_id & unit_name is Missing in Reference File |
Min Measurement Range O2 | 0 PPM Min Measurement Range O2 unit_id & unit_name is Missing in Reference File |
Min Measurement Range NH3 | 0 PPM Min Measurement Range NH3 unit_id & unit_name is Missing in Reference File |
Min Measurement Range LEL | 0 % Min Measurement Range LEL unit_id & unit_name is Missing in Reference File |
Max Measurement Range CO | 500 PPM Max Measurement Range CO unit_id & unit_name is Missing in Reference File |
Max Measurement Range H2S | 500 PPM Max Measurement Range H2S unit_id & unit_name is Missing in Reference File |
Max Measurement Range O2 | 30 % Max Measurement Range O2 unit_id & unit_name is Missing in Reference File |
Max Measurement Range NH3 | 100 PPM Max Measurement Range NH3 unit_id & unit_name is Missing in Reference File |
Max Measurement Range LEL | 100 % Max Measurement Range LEL unit_id & unit_name is Missing in Reference File |
Self-Calibrated | Yes |
Product General Attributes | |
Warranty | 2 YEARS |
Data Logging | Yes |
Power Supply Voltage | Battery Powered |
Country of Origin | Aaland Islands Country of Origin Value not available |