TRUE-RMS ELECTRONIC LOGGING MULTIMETER WITH TRENDCAPTURE

  • Quickly documents design performance and shows you graphically what happened
  • With logging and graphing capabilities, you no longer need to download logged readings to a PC to detect a trend
  • Logging function plots measurements as a single line to help detect signal anomalies over time
  • Stores up to 10,000 readings
  • Communicates with Fluke Connect via IR3000FC connector (sold separately)
  • Large 50,000 count 1/4 VGA display with white backlight
  • TrendCapture enables viewing logged readings without a PC
  • Saved measurements allow you to name and recall measurements made in the field
  • Real time clock for automatic time stamping of saved readings
  • Zoom on trend provides unprecedented ability to view and analyze TrendCapture data; zoom in up to 14 times
SKU: Fluke 287 EAN: 095969369930 Tags: , Categories:
Pay safely with Visa Pay safely with Master Card Pay safely with PayPal Pay safely with Maestro Tooltip text
Guarantee Safe and Secure Payment Checkout

Description

Fluke 287

  • Quickly documents design performance and shows you graphically what happened
  • With logging and graphing capabilities, you no longer need to download logged readings to a PC to detect a trend
  • Logging function plots measurements as a single line to help detect signal anomalies over time
  • Stores up to 10,000 readings
  • Communicates with Fluke Connect via IR3000FC connector (sold separately)

True-RMS Data Logging Multimeter with TrendCapture

The Fluke 287 True-rms Electronics Logging Multimeter with TrendCapture quickly documents design performance and graphically displays what happened. Its unique logging and graphing capabilities mean you no longer need to download logged readings to a PC to detect a trend. The Fluke 287 packs more accuracy and convenience into a handheld multimeter than ever before.

Logging Function with TrendCapture

Logging Function with TrendCapture is an essential tool for documenting the performance of your designs, processes or systems, monitoring unattended while you work on other projects. It plots measurements as a single line to help detect signal anomalies over time, storing up to 10,000 readings. Using on-board TrendCapture, you can graphically view logged readings without a PC. (Software and interface cable not included in all packages)

“i” button on board help screens

“i” button gives you instant access to on-board help screens for every measurement function. Unsure about a function? Select it and Press the “i” button for more information.

MIN / MAX recording mode

The MIN MAX Record mode captures minimum, average, and maximum input values. When the input goes below the recorded minimum value or above the recorded maximum value, the meter beeps and records the new value. The meter stores the elapsed time since the recording session was started at the same time. The MIN MAX mode also calculates an average of all readings taken since the MIN MAX mode was activated.

This mode is for capturing intermittent readings, recording minimum and maximum readings unattended, or recording readings while equipment operation precludes watching the meter. The MIN MAX mode is best for recording power supply surges, inrush currents, and finding intermittent failures.

Capturing peak values

Peak record is very similar to the MIX MAX function, with a signification difference being the shorter response time for peak recording: 250 μs. With this short response time, the actual peak values of a sinusoidal signal are measurable. Transients are more accurately measured using the peak record feature.

In the secondary area of the display, the maximum and minimum peak values as well as the average value are shown along with their respective time stamps. The time stamp next to the average value indicates the elapsed time of the peak recording session. The peak recording session start time is shown along the bottom of the page area of the display.

When the peak value of the input signal goes below the recorded minimum value or above the recorded maximum value, the Meter beeps and records the new value. At the same time, the elapsed time since the peak recording session was started is stored as the recorded value’s time stamp.

Making dB measurements

The Meter is capable of displaying voltage as a dB value, either relative to 1 milliwatt (dBm), a reference voltage of 1 volt (dBV) or a user-selectable reference value.

Screen layout

1. Softkey labels – Indicates the function of the button just below the displayed label

2. Bar graph – Analog display of the input signal

3. Relative – Indicates the displayed value is relative to a reference value

4. Minus sign – Indicates a negative reading

5. Lightning bolt – Indicates hazardous voltage present at the Meter’s input

6. Remote communication – Indicates activity over the communication link

7. Battery level – Indicates the charge level of the six AA batteries

8. Time – Indicates the time set in the internal clock

9. Mode annunciators – Indicates the meter’s mode

10. Mini measurement – Displays the lightning bolt (when necessary) and the input value when the primary and secondary displays are covered by a menu or pop-up message

11. Date – Indicates the date set in the internal clock

12. Beeper – Indicates the meter’s beeper is enabled (not associated with continuity)

13. Units – Indicates the units of measure

14. Auxiliary units – Indicates unitless measurements such as Crest Factor

15. Range indicator – Indicates the range the Meter is in and the ranging mode (auto or manual)

16. Secondary display – Displays secondary measurement information about the input signal

287 and 289 comparison

The chart below outlines main features and differences between the Fluke 287 and 289.

Features287289
Multiple on screen displays
True RMS AC bandwidth  100 kHz100 kHz
dBV/dBm
DC mV resolution 1µV 1µV
Megohm range up to 500MΩ 500MΩ
Conductance 50.00nS 50.00nS
Continuity beeper
Elapsed time / time of day clock
Min/max/avg/duty cycle/pulse width
Isolated optical interface for PC connection
Auto/touch hold
200 hours logging capacity
Low ohm capability
LoZ volts
Low pass filter

Multimeters Template

StyleHand-Held
Measures AC VYes
Measures DC VYes
Measures AC AYes
Measures DC AYes
True RMSYes
Maximum Voltage AC1000 V
Resolution AC Volts0.001 mV
Maximum Voltage DC1000 V
Resolution DC Volts0.001 mV
Maximum Current AC10 A
Minimum Current AC0.01 mA
Resolution AC Current0.01 mA
Maximum Current DC10 A
Minimum Current DC0.01 mA
Resolution DC Current0.01 A (10 mA)
Basic Accuracy V DC0.025%
# Digit Display4.5
Counts50000 .
BacklightYes
Manual/AutorangingBoth
DecibelsNo
ResistanceYes 

Resistance

Range: 500 MΩ
Resolution: 0.1 MΩ
Accuracy: 8 % + 2

FrequencyYes 

Frequency

Range: 999.99 kHz
Resolution: 0.01 kHz
Accuracy: 0.005% + 5

CapacitanceYes 

Capacitance

Range: 100 mF
Resolution: 0.1 mF
Accuracy: 2 % + 20

TemperatureYes 

Temperature

Range:
-200.0 °C to 1350.0 °C
-328.0 °F to 2462.0 °F
Resolution:
0.1 °C
0.1 °F
Accuracy:
1 % + 10
1 % + 18

Diode TestingYes 

Diode Testing

Range: 3.1 V
Resolution: 0.0001 V
Accuracy: 1 % + 20

CAT RatingIV 

CAT Rating

CAT III 1000 V / CAT IV 600 V

CAT Voltage1,000 V, 600 V
Intrinsically SafeNo
Peak HoldYes
Overload ProtectorYes
Kelvin 4-Wire Measurement CapabilityNo
Wireless DisplayNo
Data HoldYes
Low-Pass FilterNo
Duty Cycle %Range: 1.00 % to 99.00 %
Resolution: 0.01 %
Accuracy: 0.2 % per kHz + 0.1 %

Product General Attributes

Unique FeaturesLogging function with TrendCapture. Log data continuously for over 200 hours storing up to 10,000 readings. Low impedance

voltage function prevents false readings due to “ghost voltage.” Low Pass Filter for accurate voltage and frequency

measurements on adjustable speed motor drives.

Warranty10 YEARS
Warranty DetailsLimited lifetime warranty, Limited Lifetime Warranty
Safety ApprovalCE, CSA, UL
Interfaces I/O Analog Output, Analog Input
StorageHard Drive
Product Weight1.92 LBS
Product Height2.38 IN
Product Length8.75 IN
Product Width4.03 IN
Data LoggingYes
Calibration IncludedFactory Calibration
Battery TypeAA
Power Supply VoltageBattery Powered
Country of OriginUnited States
UPC095969417853

Reviews

There are no reviews yet.

Be the first to review “Fluke 287 – True-RMS Data Logging Multimeter with TrendCapture”
Weight1.92 lbs
Dimensions8.75 × 4.03 × 2.38 in
Fluke 287 – True-RMS Dat...

Original price was: $835.98.Current price is: $711.09.

Our team of knowledgeable professionals is here to help you make informed decisions. Whether you need product recommendations, technical support, or guidance on your purchase, we're just a click away.

Contact Us Now:
📧 sales@nestesinstruments.com
📞 +1 (833) 763-7837


Let us assist you in finding the perfect solution!
Have Questions? Ask an Expert!