Description
Fluke 287
- Quickly documents design performance and shows you graphically what happened
- With logging and graphing capabilities, you no longer need to download logged readings to a PC to detect a trend
- Logging function plots measurements as a single line to help detect signal anomalies over time
- Stores up to 10,000 readings
- Communicates with Fluke Connect via IR3000FC connector (sold separately)
True-RMS Data Logging Multimeter with TrendCapture
The Fluke 287 True-rms Electronics Logging Multimeter with TrendCapture quickly documents design performance and graphically displays what happened. Its unique logging and graphing capabilities mean you no longer need to download logged readings to a PC to detect a trend. The Fluke 287 packs more accuracy and convenience into a handheld multimeter than ever before.
Logging Function with TrendCapture
Logging Function with TrendCapture is an essential tool for documenting the performance of your designs, processes or systems, monitoring unattended while you work on other projects. It plots measurements as a single line to help detect signal anomalies over time, storing up to 10,000 readings. Using on-board TrendCapture, you can graphically view logged readings without a PC. (Software and interface cable not included in all packages)


“i” button on board help screens
“i” button gives you instant access to on-board help screens for every measurement function. Unsure about a function? Select it and Press the “i” button for more information.
MIN / MAX recording mode
The MIN MAX Record mode captures minimum, average, and maximum input values. When the input goes below the recorded minimum value or above the recorded maximum value, the meter beeps and records the new value. The meter stores the elapsed time since the recording session was started at the same time. The MIN MAX mode also calculates an average of all readings taken since the MIN MAX mode was activated.
This mode is for capturing intermittent readings, recording minimum and maximum readings unattended, or recording readings while equipment operation precludes watching the meter. The MIN MAX mode is best for recording power supply surges, inrush currents, and finding intermittent failures.

Capturing peak values
Peak record is very similar to the MIX MAX function, with a signification difference being the shorter response time for peak recording: 250 μs. With this short response time, the actual peak values of a sinusoidal signal are measurable. Transients are more accurately measured using the peak record feature.
In the secondary area of the display, the maximum and minimum peak values as well as the average value are shown along with their respective time stamps. The time stamp next to the average value indicates the elapsed time of the peak recording session. The peak recording session start time is shown along the bottom of the page area of the display.
When the peak value of the input signal goes below the recorded minimum value or above the recorded maximum value, the Meter beeps and records the new value. At the same time, the elapsed time since the peak recording session was started is stored as the recorded value’s time stamp.
Making dB measurements
The Meter is capable of displaying voltage as a dB value, either relative to 1 milliwatt (dBm), a reference voltage of 1 volt (dBV) or a user-selectable reference value.
Screen layout
1. Softkey labels – Indicates the function of the button just below the displayed label
2. Bar graph – Analog display of the input signal
3. Relative – Indicates the displayed value is relative to a reference value
4. Minus sign – Indicates a negative reading
5. Lightning bolt – Indicates hazardous voltage present at the Meter’s input
6. Remote communication – Indicates activity over the communication link
7. Battery level – Indicates the charge level of the six AA batteries
8. Time – Indicates the time set in the internal clock
9. Mode annunciators – Indicates the meter’s mode
10. Mini measurement – Displays the lightning bolt (when necessary) and the input value when the primary and secondary displays are covered by a menu or pop-up message
11. Date – Indicates the date set in the internal clock
12. Beeper – Indicates the meter’s beeper is enabled (not associated with continuity)
13. Units – Indicates the units of measure
14. Auxiliary units – Indicates unitless measurements such as Crest Factor
15. Range indicator – Indicates the range the Meter is in and the ranging mode (auto or manual)
16. Secondary display – Displays secondary measurement information about the input signal
287 and 289 comparison
The chart below outlines main features and differences between the Fluke 287 and 289.
Features | 287 | 289 |
Multiple on screen displays | ✔ | ✔ |
True RMS AC bandwidth | 100 kHz | 100 kHz |
dBV/dBm | ✔ | ✔ |
DC mV resolution | 1µV | 1µV |
Megohm range up to | 500MΩ | 500MΩ |
Conductance | 50.00nS | 50.00nS |
Continuity beeper | ✔ | ✔ |
Elapsed time / time of day clock | ✔ | ✔ |
Min/max/avg/duty cycle/pulse width | ✔ | ✔ |
Isolated optical interface for PC connection | ✔ | ✔ |
Auto/touch hold | ✔ | ✔ |
200 hours logging capacity | ✔ | ✔ |
Low ohm capability | ✔ | |
LoZ volts | ✔ | |
Low pass filter | ✔ |

Multimeters Template | |
---|---|
Style | Hand-Held |
Measures AC V | Yes |
Measures DC V | Yes |
Measures AC A | Yes |
Measures DC A | Yes |
True RMS | Yes |
Maximum Voltage AC | 1000 V |
Resolution AC Volts | 0.001 mV |
Maximum Voltage DC | 1000 V |
Resolution DC Volts | 0.001 mV |
Maximum Current AC | 10 A |
Minimum Current AC | 0.01 mA |
Resolution AC Current | 0.01 mA |
Maximum Current DC | 10 A |
Minimum Current DC | 0.01 mA |
Resolution DC Current | 0.01 A (10 mA) |
Basic Accuracy V DC | 0.025% |
# Digit Display | 4.5 |
Counts | 50000 . |
Backlight | Yes |
Manual/Autoranging | Both |
Decibels | No |
Resistance | Yes Resistance Range: 500 MΩ |
Frequency | Yes Frequency Range: 999.99 kHz |
Capacitance | Yes Capacitance Range: 100 mF |
Temperature | Yes Temperature Range: |
Diode Testing | Yes Diode Testing Range: 3.1 V |
CAT Rating | IV CAT Rating CAT III 1000 V / CAT IV 600 V |
CAT Voltage | 1,000 V, 600 V |
Intrinsically Safe | No |
Peak Hold | Yes |
Overload Protector | Yes |
Kelvin 4-Wire Measurement Capability | No |
Wireless Display | No |
Data Hold | Yes |
Low-Pass Filter | No |
Duty Cycle % | Range: 1.00 % to 99.00 % Resolution: 0.01 % Accuracy: 0.2 % per kHz + 0.1 % |
Product General Attributes | |
Unique Features | Logging function with TrendCapture. Log data continuously for over 200 hours storing up to 10,000 readings. Low impedance voltage function prevents false readings due to “ghost voltage.” Low Pass Filter for accurate voltage and frequency measurements on adjustable speed motor drives. |
Warranty | 10 YEARS |
Warranty Details | Limited lifetime warranty, Limited Lifetime Warranty |
Safety Approval | CE, CSA, UL |
Interfaces I/O | Analog Output, Analog Input |
Storage | Hard Drive |
Product Weight | 1.92 LBS |
Product Height | 2.38 IN |
Product Length | 8.75 IN |
Product Width | 4.03 IN |
Data Logging | Yes |
Calibration Included | Factory Calibration |
Battery Type | AA |
Power Supply Voltage | Battery Powered |
Country of Origin | United States |
UPC | 095969417853 |
Reviews