Description

Fluke 754/154 BU
- Large Easy to Read Display
- USB Connectivity
- HART Connectivity
- Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 1 ms
- Bright white dual display. Read both sourced and measured parameters simultaneously.
- Long range wireless communication up to 250 feet
Process Calibrator and 154 HART Calibration Assistant Bundle w/ Rugged Case
Introducing the Fluke 754 Documenting Process Calibrator with HART communication capability. Fluke has designed the 754 to withstand the trial of everyday use with a rugged exterior shell. It is the perfect tool for calibration, maintenance and troubleshooting HART and other instruments.
The Fluke 754 is designed to be an all-in-one tool. Its small size packs a number of important tools including sourcing, simulating pressure, measuring pressure, temperature and electrical signals. Even with all of these tools, the 754 manages to keep a user friendly interface and an easy to read large screen. The lithium ion battery provides longer life and a USB connection provides PC connectivity.
| Capability | 753 | 754 |
| Source/measure | ● | ● |
| Automated procedures | ● | ● |
| Results capture | ● | ● |
| Uses all Fluke pressure modules | ● | ● |
| Transmitter mode | ● | ● |
| Capability | 753 | 754 |
| Serial interface | ● | ● |
| Data logging | ● | ● |
| HART communications | ● | |
| Pulsed RTD simulation to 1 ms | ● | ● |
| Li-ion battery with “Gas Gauge” | ● | ● |
Compatability
The Fluke 754 is built to work in a variety of applications. It works with Fluke software and a assortment of other platforms including Emerson, Honeywell, Cornerstone, Yokogawa, Prime Technologies and Intergraph. The 754 is simple to use and makes it easy to create procedures, instructions and action lists to delivery quickly with simple documentation.
HART Communication
- No required external box or secondary tool for HART calibration or maintenance
- Fast HART communications
- Supports popular models of HART transmitters
- More devise-specific command support than any other HART field calibrator
- Works with multiple masters, burst mode, and multi-drop configurations.
- Is easy to update as additional instruments are added
- Interrogate to determine device type, manufacturer, model, tag.
- Reconfigure the sensor mapping of dual sensor temperature transmitters.
- Read HART PV function and smart transmitter while measuring analog mA output.
- Read and write HART configuration functions to make field adjustments
- Re-label smart transmitters by reading and writing to the HART tag field.
Additional Features
Automated Procedures
Setting up automated calibration procedures with the Fluke 754 is simple. They can be used in a variety of applications including linear transmitters, DP flow transmitters, and one & two point limit switches. After set up, the 754 will perform the necessary tests and calculate any errors. Users can then easily view final results and quickly locate out of tolerance points.
Custom Units
Gives users the ability to map one unit of measurement to another such as mV to ºC or ºF. This allows the 754 to be used with accessories that output in mV and still properly document th test using an unsupported unit of measurement including parts per million or rpm.
User-entered Values
Give users the ability to record results from external measurements devices such as a panel meter. This allows for comprehenssive data recording.
Limit Switch Calibration
Limit switch calibration is simple and fast with the 754’s automated procedures. Procedures can be used for either one or two point switches and measure voltage, current, pressure and temperature.
Differential Pressure Flow Instrument Calibration
Built in square root functions quickly calibrate DP flow instruments.
Multifunctional
The 754 is able to calibrate temperature, pressure, voltage, current, resistance, and frequency. With these capabilities and the ability to both measure and source, the 754 can troubleshoot and calibrate.
Powerful & Simple
Users will find the Fluke 754’s user interface easy to navigate and follow step by step through each procedure. Have your unit up and running with in a few minutes. Saving valuable time and money.
Records and documents results
The Fluke 754 seemlessly records all calibration data, perminately eliminating the need to transcribe results on a computer or piece of paper. This ensures that all results are recorded properly. The USB connection allows for easy data transfer to your computer.
Truly hand-held
Despite all of its features, the 754 is still able to maintain a compact and easy to transport design. It is compact enough to fit into most tool bags and can be used in tight work areas. The rechargeable lithium ion battery provides enough battery for a standard day’s use (approximately 10 hours)
Bright white display
The bright white display featured on the 754 offers users the ability to view results in real time indoors or outdoors. With 3 brightness settings, this display will work in any environment.
Soft keys
Fluke has added soft keys to the 754 giving users instant access to task lists, automated procedures, scaling, min/max, stepping and ramping, and review memory.
Rugged and reliable
Fluke has designed the 754 to withstand the rigors of daily usage. The strong urethane case can withstand the rough conditions brought on by an industrial environment.
Built-in algebraic calculator
Built-in math functions eliminate the need to make separate calculations after data is recorded. Eliminating opportunity for error during data transcription.
Operating Modes
Designed to be an all-in-one tool, the 754 has three separate operating modes including measure, source and a combination of both measure and source. This eliminates the need for multiple tools.
Fluke 154 HART Calibration Assistant
- Monitor device PV, SV, TV, QV and other measured HART variables
- Easy to use, fast connect and view HART data
- Perform HART trim on HART devices when used with a Fluke 750, or 720 series calibrator

HART Calibration Assistant.
The Fluke 154 is a standalone tablet based HART ® communication tool. The tablet configured with the “FlukeHART” mobile app utilizes a wireless HART modem that connects directly to the HART transmitter being tested or configured. When you combine your Fluke 154 HART Calibration Assistant with a Fluke 750 Series Documenting Process Calibrator, or a 720 Series Multifunction Process Calibrator you have a complete HART calibration and con- figuration solution.
The 154 puts HART device configuration at your fingertips. An Android™ based tablet user interface makes HART configuration easy. The external wireless modem allows you to connect the modem to the transmitter being tested so you can communicate to the device remotely. HART transmitters can often be found in confined spaces that are difficult to access, or are out of reach. The Fluke 154 helps reduce the need to stand right next to the device being tested or configured so you can work from a safer, more convenient location.
- Multiple language support: Select language from the Android operating system. Hart communication commands are limited to English per the HART device descriptions.
- Wireless HART Modem: Includes configurable connection cable that accepts either the hook clips for connecting to wires or the extended tooth alligator clips designed to connect to transmitter connection screw heads. Rechargeable lithium-ion battery lasts easily for several days of HART device configuration and testing activities. Rugged enclosure and test lead set designed for process environments
- Store device configurations: Store HART device configurations in ASCII or PDF file configurations.
- HART support: Complete access to all features of the HART device’s DD including methods. Meets HART physical layer specification: HCF_SPEC-54
- DD updates: Download free DD updates from Fluke.com for 3-years. Updates available when DD updates released from the HART FieldComm group (approximately four times a year).
- Hard side case: Protects and stores tablet, modem, test leads and connection cable in a light- weight durable tote that is easy to carry.
Process / Calibration/Multifunction Calibrators Template | |
|---|---|
| Type | Hand Held |
| Measure Voltage | Yes |
| Loop Voltage Min | 0.005 mV (0.000005 V) |
| Simulate Loop Voltage | Yes |
| Loop Voltage Max | 26 V |
| Voltage Measurement Max | 300 V |
| Voltage Measurement Min | 0.005 mV (0.000005 V) |
| Source/Simulate DC Current | Yes |
| Measure DC Current | Yes |
| Current Measurement Max | 110 mA |
| Current Measurement Min | 5 uA (0.005 mA) |
| Source/Simulate Resistance | Yes |
| Measure Resistance | Yes |
| Resistance Measurement Max | 10 K Ohms (10000 Ohms) |
| Resistance Measurement Min | 50 M Ohms (50000000 Ohms) |
| Source/Simulate Frequency | Yes |
| Measure Frequency | Yes |
| Frequency Measurement Max | 50 kHz (50000 Hz) |
| Frequency Measurement Min | 0.01 Hz |
| Measure RTD | Yes |
| Measure Thermocouples | Yes |
| Source/Simulate Pressure | No |
| Pressure Modules Available | Yes |
| Hart Compatible | Yes |
| FieldBus Compatible | No |
| Data Log Functions | Current, Frequency, Resistance, Temperature, Voltage |
| Backlighted | Yes |
| Graphical Screen | No |
| Types RTD/Thermocouples Accepted | B, C , E, J, K, L, N, R, S, T, U Types RTD/Thermocouples Accepted Also woks with BP and XK Thermocouples. |
| Intrinsically Safe(Calibrators) | No |
Product General Attributes | |
| Unique Features | Holds up to a full week of downloaded procedures and calibration results. Use many features like autostep, custom units, user entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay etc. Rechargeable Li-Ion battery for 10 hour uninterrupted use. Includes gas gauge. Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 1 ms. |
| Warranty | 3 YEARS |
| Safety Approval | CSA |
| IP Rating | IP52 |
| Product Weight | 2.7 LBS |
| Product Height | 7.87 IN |
| Product Length | 16.14 IN |
| Product Width | 11.02 IN |
| Shipping Weight | 11.2 LBS |
| Data Logging | Yes |
| ECCN Number | 3A992 |
| Calibration Included | NIST Calibration |
| Battery Type | Li-ion |
| Power Supply Voltage | Battery Powered |
| Country of Origin | United States |
| Shipping Height | 7.87 IN |
| Shipping Length | 16.14 IN |
| Shipping Width | 11.02 IN |








Reviews