Description

Fluke 87V-MAX
- Contains all features of the 87-5, but with several enhancements
- IP67 rating (waterproof and dustproof)
- 800-hour battery life
- Drop tested to 4 meters
- Backlit keypad for increased visibility
True RMS Digital Multimeter
The 87V MAX contains all the trusted features of the most popular digital multimeter used today, the Fluke 87V, and then some. From wet, dusty, or dark environments to long days, the 87V MAX was designed to help you finish the most on a work site. It features a unique function for accurate voltage and frequency measurements on variable frequency motor drives (VFDs) and other electrically noisy equipment; using True-RMS AC voltage and current for accurate measurements on non-linear signals.
For use in extreme environments
The Fluke 87V MAX True-RMS Digital Multimeter defines a new standard for operating in extreme conditions, with the features and accuracy to troubleshoot most electrical problems. The 87V MAX has an IP67 (waterproof and dustproof) rating, an extended operating temperature range of -15°C to +55°C (5°F to 131°F, -40°C for up to 20 minutes), and 95% humidity, and has been designed and tested to withstand a 4m (13 ft) drop. The Fluke 87V MAX True RMS Digital Multimeter is built to work in the toughest environments you might face.
The 87V MAX also has an industrial-strength outer shell and a removable holster that doubles as test lead storage and a test probe holder for one-handed operation.



Screen layout
1. Polarity indicator of bar graph, positive/negative slope indicator for triggering | 10. Min/max recording mode |
2. Continuity beeper is on | 11. Low pass filter mode |
3. Relative mode | 12. Low battery |
4. Smoothing | 13. Units of measure |
5. Indicates negative reading | 14. Temperature |
6. High voltage is present | 15. Selected range |
7. Auto hold | 16. High resolution mode |
8. Display hold | 17. Auto/manual ranging |
9. Peak min max mode (250µs response time) | 18. Bar graph |
Product comparison
The chart below outlines a comparison of the 87-5 and several other Fluke products.
To view additional selection criteria for the Fluke digital multimeter portfolio, please click here.
87V | 87V MAX | 289 | 179 | 1587 FC | |
Counts | 20000 | 20000 | 50000 | 6000 | 6000 |
Basic DC accuracy | 0.05% | 0.05% | 0.02% | 0.09% | 0.09% |
True RMS | ✓ | ✓ | ✓ | ✓ | ✓ |
AC/DC voltage | 1000V | 1000V | 1000V | 1000V | 1000V |
AC/DC current | 10A | 10A | 10A | 10A | 10A |
Resistance | 50MΩ | 50MΩ | 500MΩ | 50MΩ | 50MΩ |
Capacitance | 9999µF | 9999µF | 100000µF | 9999µF | 9999µF |
Temperature | 1994°F | 1994°F | 2462°F | 752°F | 932°F |
Frequency | 200 kHz | 200 kHz | 1 MHz | 100 kHz | 100 kHz |
Motor drive measurement | ✓ | ✓ | ✓ | – | ✓ |
Relative reference | ✓ | ✓ | ✓ | – | – |
Microamps | ✓ | ✓ | ✓ | – | – |
Conductance | 50nS | 60nS | 50nS | – | – |
Duty cycle | ✓ | ✓ | ✓ | – | – |
Pulse width | – | – | ✓ | – | – |
Pi/DAR | – | – | – | – | ✓ |
Drop test | 3 meters | 4 meters | – | – | – |
Backlit keypad | – | – | – | – | |
IP rating | IP30 | IP67 | IP42 | – | – |
CAT III rating | 1000V | 1000V | 1000V | 1000V | 1000V |
CAT IV rating | 600V | 600V | 600V | 600V | – |
Battery life | 400 hours | 800 hours | 200 hours | 200 hours | 1000 hours |

Multimeters Template | |
---|---|
Style | Hand-Held |
Measures AC V | Yes |
Measures DC V | Yes |
Measures AC A | Yes |
Measures DC A | Yes |
True RMS | Yes |
Maximum Voltage AC | 1000 V |
Resolution AC Volts | 0.1 mV |
Maximum Voltage DC | 1000 V |
Resolution DC Volts | 0.1 mV |
Maximum Current AC | 10 A Maximum Current AC 20 A for 30 seconds maximum |
Minimum Current AC | 0.1 uA (0.00010 mA) |
Resolution AC Current | 0.1 uA (0.00010 mA) |
Maximum Current DC | 10 A Maximum Current DC 20 A for 30 seconds maximum |
Minimum Current DC | 0.1 uA (0.00010 mA) |
Resolution DC Current | 0.1 uA (0.00010 mA) |
Basic Accuracy V DC | ± (0.05 % + 1) |
# Digit Display | 4.5 |
Counts | 6000 . Counts 6000 counts updates 4/sec; 19,999 counts in high-resolution mode |
Backlight | Yes |
Manual/Autoranging | Both |
Decibels | No |
Resistance | Yes Resistance Maximum Resistance 50 Ω |
Frequency | Yes Frequency Maximum Frequency 200 kHz |
Capacitance | Yes Capacitance Maximum Capacitance 9,999 µF |
Temperature | Yes Temperature Range: 200.0°C – 1090°C, -328.0°F – 1994.0°F; |
Diode Testing | Yes Diode Testing Range 3 V |
CAT Rating | IV CAT Rating CAT III 1000 V / CAT IV 600 V |
CAT Voltage | 1,000 V, 600 V |
Intrinsically Safe | No |
Peak Hold | Yes |
Overload Protector | Yes |
Kelvin 4-Wire Measurement Capability | No |
Wireless Display | No |
Data Hold | Yes |
Low-Pass Filter | Yes |
Duty Cycle % | Range: 0.0 to 99.9 % Accuracy: Within ± (0.2 % per kHz + 0.1 %) for risetimes < 1 μs |
Product General Attributes | |
Unique Features | •Unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment •Built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument •Optional magnetic hanger for easy set-up and viewing while freeing your hands for other tasks •Large digit display with bright, two-level backlight makes the 87V significantly easier to read than older models •True-rms ac voltage and current for accurate measurements on non linear signals •Selectable filter for accurate voltage and frequency measurements on motor drives •0.05 % dc accuracy •6000 counts, 3-3/4 digits •4-1/2 digit mode for precise measurements (20,000 counts) •Measure up to 1000 V ac and dc •Measure up to 10 A, 20 A for up to 30 seconds •Built in thermometer lets you carry one less tool (TC probe included) •Frequency to 200 kHz and % duty cycle •Resistance, continuity and diode test |
Warranty | 10 YEARS |
Additional Info/Comments | •10,000 µF capacitance range for components and motor caps •Min/Max-Average recording with Min/Max Alert to capture variations automatically •Peak capture to record transients as fast as 250 µs •Relative mode to remove test lead interference from low ohms measurements •Auto and manual ranging for maximum flexibility •Touch Hold to capture stable readings avoiding noisy signals •Large display digits and two-level bright white backlight for increased visibility •Analog bargraph for fast changing or unstable signals •Input Alert provides audible warning against wrong use of input jacks •Improved selectable sleep mode for long battery life •Access door for fast battery changes without breaking the calibration seal •”Classic” design with new removable holster with built in test lead and probe storage •Lifetime warranty |
Safety Approval | CSA, UL Safety Approval Designed to comply with IEC 1010-1 as a 1000V, CAT III instrument (see pg.2 for |
Interfaces I/O | Other, Analog Input |
Product Weight | 1.54 LBS Product Weight With Holster |
Product Height | 2.5 IN |
Product Length | 7.8 IN |
Product Width | 3.93 IN |
Data Logging | No |
ECCN Number | 3A992 |
Calibration Included | Factory Calibration |
Battery Type | AA |
Power Supply Voltage | Battery Powered |
Country of Origin | United States |
UPC | 095969245241 |