Gossen M502B Mavolux 5032C Digital Footcandle and Lux Meter

Brand:
Please, activate Wishlist option to use this widget.
Please, activate Compare option to use this widget.
20 people are viewing this product right now

$536.86

Shipping calculated at checkout.
or
Add to quote
Estimated delivery:4 days

MAVOLUX 5032 C BASE

  • Sensor cable is permanently attached.
  • No USB port or PC Software for this version
  • Precision meters for measuring the illuminance in Lux and Footcandles in accordance with IEC 13032-1, Appendix B
  • The silicon photo diode is color corrected, i.e. its spectral response is matched to the photopic daylight vision of the human eye V(?).
  • Cosine correction for light incidence at an angle
  • Easy to use
  • 3 ½ digits display
  • Backlight display (only in MAVOLUX 5032 B USB)
  • Data storage of up to 100 measurements
  • Auto and manual range selection
  • CD-Rom with software for processing data, and controlling the meter
  • Compact carry case and USB cable included

Applications:
 

  • Light technicians
  • Control of light sources
  • Street lights
  • Lighting of work places, public buildings, sports facilities
  • Quality control and quality assurance in the manufacture of lamps and light sources
  • Light boards / LED billboards
  • Light designers and architects
  • Measurements in agriculture and horticulture
Pay safely with Visa Pay safely with Master Card Pay safely with PayPal Pay safely with Maestro Tooltip text
Guarantee Safe and Secure Payment Checkout

Description

Gossen M502B Mavolux 5032C Digital Footcandle and Lux Meter

Gossen M502B Mavolux 5032C Digital Footcandle and Lux Meter

The Mavolux 5032 B & C are high precision luxmeter’s that are optimally suited for measuring very high light intensities (brightest daylight, head lights, etc.) without any additional accessories. Each has a USB interface for powering the meter, meter control, and data display/storage using GLUX 2 software (included). The Mavolux 5032 C is typically used in general applications and the Mavolux 5032 B has improved low light sensitivity for certification and inspection applications. The MAVOLUX 5032 B has been approved for certification and official inspection procedures. Sensor cable is permanently attached.

MAVOLUX 5032 C BASE

Due to its class C accuracy, this meter is used primarily as an industrial measuring instrument for planning, installing, inspecting and monitoring lighting systems, as well as for the assurance of compliance with specified lighting conditions.

Its four measuring ranges with automatic or manual range selection cover a broad span from 0.1 to 199,900 lx with an accuracy level of ± 3% ± 1 digit. V( λ ) matching deviation, which amounts to f1‘ < 7.5%, is considerably better than the permissible error limit for class C specified in the standards. At GOSSEN, great emphasis is placed upon reliability by means of calibration. For purposes of substantiation, a factory calibration certificate or a DAkkS calibration certificate can be ordered along. Depending on how the meter is used, we recommend a calibration interval of 12 to 24 months.

The Gossen Mavolux 5032C is a handy, easy to use, highly accurate light meter capable of measuring illumination in either foot candles or lux. Candelas/m2 and footlamberts can also be measured with the optional luminance attachment (4141).

The Mavolux 5032C is equipped with color correction, so that its spectral response is matched to that of the human eye, in accordance with DIN 5032, part 7, class C. Integrated cosine correction is included in order to assure that oblique incident light is also evaluated correctly.

Digital Luxmeters and Footcandle meters for industry, trade, electricians, architects, institutes, inspection authorities and also photo and film studios meet classifications of DIN 5032/T7 and CIE no. 69. Even very strong light (e.g. from car headlights) can be measured without any additional accessories.

Mavolux 5032 C
MethodClass C DIN 5032-7 / EN 13032-1, appendix B
Error limit – overall error, typical≤ 15 %
Accuracy± 3 % of reading ± 1 Digit
Mavolux 5032 B
MethodClass B DIN 5032-7 / EN 13032-1, appendix B
Error limit – overall error, typical≤ 8%
Accuracy± 3 % of reading ± 1 Digit

Product General Attributes

HTS/Schedule B Number9027.89.8090
ECCN NumberEAR99
Country of OriginGermany

Reviews

There are no reviews yet.

Be the first to review “Gossen M502B Mavolux 5032C Digital Footcandle and Lux Meter”
Gossen M502B Mavolux 5032C Dig...

$536.86

Our team of knowledgeable professionals is here to help you make informed decisions. Whether you need product recommendations, technical support, or guidance on your purchase, we're just a click away.

Contact Us Now:
📧 sales@nestesinstruments.com
📞 +1 (833) 763-7837


Let us assist you in finding the perfect solution!
Have Questions? Ask an Expert!