Description
Hioki DT4224 – Digital Multimeter with C/R Measurement For General Use

- Capacitance: 1.000 μF to 10.00 mF
- Diode check
- Non Circuit Breaker Tripping Design
- 6000 Display Count
- Auto hold for easy checking of the display
- Visual Warning Function
It’s extremely dangerous to measure a commercial power supply with an instrument set to the resistance range (used to measure continuity, capacitance, and diodes). Doing so can cause electrical equipment to stop operating due to tripped circuit breakers or result in arcing.
The Hioki DT4224 Digital Multimeter prevents potential hazards that can be caused by erroneous instrument operation with a one-of-a-kind design. With the DT4224 the measurement circuit is switched after the instrument detects resistance, continuity, capacitance, or diode input. Even if you mistakenly input voltage with the instrument set to the resistance range, the high input impedance will limit the current flowing to the instrument to 1.5 mA or less to prevent potential hazards. When the DT4224 detects resistance, continuity, capacitance, or diode input, the LoZ icon is shown on the display, allowing you to identify at a glance which measurement circuit has been selected.
The Hioki DT4200 Digital Multimeter Series consists of a diverse array of meters ranging from professional to industrial to pocket meters, delivering a super fast response rate and safety features that take electrical testing to a higher level. The Hioki DT4224 is a pocket-sized digital multimeter featuring an innovating circuit-breaker false trip prevention function to enhance testing safety, capacitance and diode testing functions, ideal for all general electrical jobs.
Mistakenly tripped circuit breakers and arcs due to careless input of voltage to the resistance range can be extremely hazardous
The DT4223 and DT4224 feature a new proprietary function that prevents accidents resulting from breakers that mistakenly trip due to incorrect input.
Erroneous circuit-breaker activation
Arcing and sparks
Conventional Digital Multimeters
Because changing the measurement range also changes the measurement circuit, mistakenly inputting voltage with the instrument set to the resistance range will cause a large current to flow to the device, leading to hazards such as tripped circuit breakers and arcing.

Voltage range measurement circuit

Resistance range measurement circuit

DT4223 / DT4224 Digital Multimeter
The measurement circuit is switched after the instrument detects resistance, continuity, capacitance, or diode input. Even if you mistakenly input voltage with the instrument set to the resistance range, the high input impedance will limit the current flowing to the instrument to 1.5 mA or less to prevent potential hazards.

Resistance range measurement circuit

Input-based switching of the measurement circuit

Safe testers that protect workers from dangerous accidents
Engineered based on extensive customer feedback, the Hioki Digital Multimeter DT4200 series delivers the design and quality needed in order to ensure safety in field measurement.
Prevent unavoidable debris from shorting the measurement target and causing an accident.
The DT4255’s voltage input terminals incorporate a protective fuse so that contamination of the instrument’s internal components with iron powder or other particulate matter will not result in an internal short-circuit. The fuse can be replaced easily on site.
Continued high input may result in major accidents such as fire.
To prevent an accident, a warning function immediately notifies the operator if the DMM receives excessively high input.
*Red screen available on high-end models and DT4223/DT4224 only.
Wrong insertion may lead to short-circuits.
The DT4281 and DT4282 use terminal shutters to keep probes from being inserted into the wrong inlets. The shutters block whichever terminal is not being used based on the selected measurement function.
Mistakenly measuring voltage using the current range may lead to a short-circuit.
The DT4281, DT4253, DT4255, and DT4256 eliminate the root cause of such accidents by providing clamp-on sensor- based current measurement functionality instead of using conventional probes.
Safe measurement requires use of an instrument that suits the measurement location.
To ensure operators’ ability to use measuring instruments safely, IEC 61010 classifies the locations in which instruments are used into a series of safety-based measurement categories (ranging from CAT II to CAT IV). Using an instrument that does not satisfy the required safety level can lead to an electrical accident.
Designed and manufactured in Japan to ensure high quality and guaranteed with a 3-year warranty for peace of mind
All development, design, and manufacturing processes for almost all Hioki digital multimeters are carried out at our Head Office in Nagano Prefecture. Some of the industry’s most advanced technological capabilities enable us to deliver products of the highest possible quality.
Field-Proven Strength and Usability DT4200 series
Robust design capable of withstanding a drop from a height of 1 m onto concrete
To test our products’ ability to withstand mechanical shock, we repeatedly drop them from a height of at least 1 m until they break. This drop-testing regime leads to more robust products by fostering a series of design improvements.


Preventing instrument failure by keeping out dust
If dust gets into the instrument’s enclosure, it can cause the device to fail. Since dust can get into the instrument especially easily through the gap around the rotary switch, the DT4200 series incorporates a dust- proof part known as an O-ring where the rotary switch is mounted to improve the device’s dust resistance.
Fast, accurate measurement of the output voltage on the secondary side of an inverter
The DT series can accurately measure the voltage on the secondary side of an inverter, just like a power meter. Its low-pass filter rejects harmonic components so that the fundamental wave can be isolated and accurately measured.
The DT series can accurately measure the voltage on the secondary side of an inverter, just like a power meter. Its low-pass filter rejects harmonic components so that the fundamental wave can be isolated and accurately measured.
True RMS measurement for accurate measurement of even distorted current waveforms
Current waveforms are often distorted, causing the average-value and true RMS measurement methods to yield different results. To obtain accurate readings, RMS measurement is indispensable.
Outstanding viewing angle so display is easy to read at an angle or even in a dim location
The DT4200 series features a display with a wide viewing angle and a backlight function so that it’s easy to read, even when you can’t view the screen from the front or when making measurements in a dim location.
Outstanding hands-free ease of use in the field when working with numerous measurement locations
It’s hard to carry out work tasks smoothly when you’re juggling a measuring instrument, probes, recording paper, and other supplies. Field concerns like these are resolved by the DT4200’s magnetic strap, auto-hold function, and ability to save results in its internal memory. These capabilities boost work efficiency and help reduce work times.
*The auto-hold function is available exclusively in high-end, standard models and DT4223,DT4224. The ability to save results in internal memory is available exclusively in high- end models.
Extensive selection of probe tips that you can choose based on the measurement location, improving ease of measurement
With the DT4200, you can choose the probe type that best suits your measurement location, making it possible to measure in areas that can’t be reached with conventional probes and busbars that you wish to clamp between probes.
*Compatible probe tips vary with the DMM model. The optional Connection Cable L4930 is required in order to use the probes shown at the left.
Multimeters Template | |
---|---|
Style | Hand-Held |
Measures AC V | Yes |
Measures DC V | Yes |
Measures AC A | No |
Measures DC A | No |
True RMS | Yes |
Maximum Voltage AC | 600 V |
Resistance | Yes |
Kelvin 4-Wire Measurement Capability | No |
Product General Attributes | |
Product Height | 1.75 IN |
Product Length | 7.25 IN |
Product Width | 3.90 IN |
Country of Origin | Japan |
Shipping Height | 1.75 IN |
Shipping Length | 7.25 IN |
Shipping Width | 3.90 IN |
Reviews
There are no reviews yet.