WooCommerce Themes

Need help? Call us:

+1 (833) 763-7837

Menu Categories

Phenix HC40C – Circuit Breaker Test Set (40,000A out, 240V/380-480V Input)

Brand:
27 people are viewing this product right now

$58,350.00

Shipping calculated at checkout.
or
Add to quote
Estimated delivery:3 days

Circuit Breaker Test Set (40,000A out, 240V/380-480V Input)

  • *** Built to order based on input voltage requirements. Please contact us prior to purchase. ***
  • *** AC power input wire and plug not included ***
  • Fully automated testing
  • Precise, repeatable current pulses with minimal distortion
  • Current wave form display
  • Test virtually any low voltage, molded case, or metal clad direct acting AC circuit breaker by simulating overload and fault conditions
  • Test current transformers and thermal or magnetic motor overload relays
  • Can be used for substation maintenance, primary injection testing on high voltage circuit breakers and protective relays
Pay safely with Visa Pay safely with Master Card Pay safely with PayPal Pay safely with Maestro Tooltip text
Guarantee Safe and Secure Payment Checkout

Description

Phenix HC40C

  • Fully automated testing
  • Precise, repeatable current pulses with minimal distortion
  • Current wave form display
  • Test virtually any low voltage, molded case, or metal clad direct acting AC circuit breaker by simulating overload and fault conditions
  • Test current transformers and thermal or magnetic motor overload relays

Circuit Breaker Test Set (40,000A out, 240V/380-480V Input)

Several versions available with varying voltage and current capacities. Please see the tables below for comparisons.

Input Voltages and Currents

HC12CHC20CHC40CHC75C
240 V, 60 A, 60 Hz240 V, 150 A, 60 Hz240 V, 320 A, 60 HzNo 240 V option
480 V, 30 A, 60 Hz480 V, 75 A, 60 Hz480 V, 160 A, 60 Hz480 V, 400 A, 60 Hz
400 V, 30 A, 50 Hz400 V, 75 A, 50 Hz400 V, 160 A, 50 Hz400 V, 400 A, 50 Hz


Notes:

  • *** Input voltages, currents, and frequencies must be specified at order time ***
  • *** AC power input wire and plug not included ***
  • 50 Hz or 60 Hz must be specified
  • Input currents based on 30-minute output ratings. Other input voltages are available, for example, 380 V, 50 Hz or 600 V, 60 Hz

Number of Taps

HC12CHC20C HC40C HC75C
# of Taps3468

Output Voltages

HC12CHC20CHC40CHC75C
Parallel6.25 V, 50 Hz8.3 V, 50 Hz10 V, 50 Hz13.3 V, 50 Hz
7.5 V, 60 Hz10 V, 60 Hz12 V, 60 Hz16 V, 60 Hz
Series12.5 V, 50 Hz16.6 V, 50 Hz20 V, 50 Hz26.6 V, 50 Hz
15 V, 60 Hz20 V, 60 Hz24 V, 60 Hz32 V, 60 Hz

Output Currents

Duty CycleHC12CHC20CHC40CHC75C
ParallelContinuous Duty1200 A2000 A4000 A7500 A
30 min ON / 30 min OFF1700 A3000 A6000 A10,000 A
1 min ON / 10 min OFF2500 A4500 A9000 A15,000 A
1 sec ON / 2 min OFF12,000 A20,000 A40,000 A75,000 A
SeriesContinuous Duty600 A1000 A2000 A3750 A
30 min ON / 30 min OFF850 A1500 A 3000 A5000 A
1 min ON / 10 min OFF1250 A2250 A4500 A7500 A
1 sec ON / 2 min OFF6000 A10,000 A20,000 A 37,500 A

Safety and Design Features

  • Circuit breaker protection
  • Control power switch with indicator and Output On indicator
  • Interlock open indicator
  • Emergency Off pushbutton
  • Highly reliable SCR’s combined with programmable phase angle firing system
  • Continuously variable output over entire test range utilizing a motorized vernier and programmable tap selector allowing for both auto-jog and current-hold capabilities
  • Sensing circuit selectable between current or contacts
  • Digital AC voltmeter for monitoring input, output, and external voltage up to 600 VAC
  • Current meter accuracy 0.8% of reading +0.3% of range
  • Meters calibrated with standards certified by NIST
  • Standard HCSS1 and HCSS2 stab sets supplied with optional stab sets available
  • Operation/maintenance manual

Computer-Control via WIN HC Software

User-friendly, menu-driven commands provide advanced database and report capabilities for test duplication and recall, report generation, and current wave shape display.

Testing Modes

  • Normal – the operator manually controls all functions of the test set.
  • Jog-to-Hold – the test set jogs the output on at “Jog on Cycles” and off for “Jog off Secs” and raises the output until the “Hold Amps” is reached.
  • Jog-to-Trip – the test set jogs the output on at “Jog on Cycles” and off for “Jog off Secs” until the circuit breaker under test trips.
  • Current Hold – the output is held to within 1% of the “Hold Amps”.
  • Memory – used for testing the sensitivity pickup of electronic controllers (when the stop button is pressed, the current level is recalled).

Programmable Phase Angle Firing

This feature assures precisely repeatable current pulses with minimal distortion and DC offset. This is achieved by combining the use of highly reliable SCR’s and computer-controlled firing system.

Wave Form Display

This feature allows for viewing of the current wave form injected through the breaker. Detection of DC offset or contact bounce can be seen. With the use of the programmable phase angle firing circuit, DC offset may be corrected by varying the firing phase angle.

None

Reviews

There are no reviews yet.

Be the first to review “Phenix HC40C – Circuit Breaker Test Set (40,000A out, 240V/380-480V Input)”

Manuals/Guides

BrochuresManuals
Phenix HC40C – Circuit B...

$58,350.00

Our team of knowledgeable professionals is here to help you make informed decisions. Whether you need product recommendations, technical support, or guidance on your purchase, we're just a click away.

Contact Us Now:
📧 sales@nestesinstruments.com
📞 +1 (833) 763-7837


Let us assist you in finding the perfect solution!
Have Questions? Ask an Expert!