Description
- Easy to use –With the PIECAL 422 you can check & calibrate all your thermocouple instruments and measure thermocouple sensors.
- Take it without into the shop, plant or field – Carry it without worry – it comes protected with a rubber boot and rugged, low profile switch. Easy to operate even in the dark areas of the plant with the backlit display.
- Calibrate directly in temperature (°C & °F) – Stop carrying around a millivolt source and thermocouple tables. The PIECAL 422 works with the thermocouples you use including types J, T, E, K, R, S, B, N, G, C, D, L (J-DIN), U (T-DIN) and Platinel II. Easily set any value quickly to within 0.1° with the adjustable digital potentiometer “DIAL” plus store any three temperatures for instant recall with the EZ-CHECK™ switch.
- Calibrate quickly with automatic output stepping – Choose between 2, 3, 5, 11 and 21 steps to automatically increment the output in 100%, 50%, 25%, 10% or 5% of span. Select the step time to match your system from 5, 6, 7, 8, 10, 15, 20, 25, 30 and 60 seconds.
- Compatible with all process instruments – Connect directly to the thermocouple inputs of smart transmitters, PLCs, DCS and multichannel recorders and verify their outputs or displays.
- Measure Thermocouple Sensors – Trouble shoot sensor connections and find broken wires. The PIECAL 422 measures the thermocouple in degrees C or F. Secondary display shows the millivolt value corresponding to the thermocouple temperature as well as the cold junction temperature measured by the calibrator.
- Evolutionary design – PIECAL Calibrators are designed and built by members of the same team that designed and built the calibrators manufactured by Fluke* under the Altek* label. The PIECAL 422 improves upon other brands by including a rubber boot, tilt stand, backlit display with larger digits, rugged switches and a battery compartment for fast battery changes.
Advantages of the PIECAL 422 over the Altek 422
![]() |
| ![]() |
Process / Calibration/Temperature Calibration/Thermocouple Calibrators Template | |
|---|---|
| Type | Hand Held |
| Measure Inputs | Yes |
| Source Outputs | Yes |
| Display (Thermocouple Calibrators) | Digital |
| Thermocouple Selection | B, C, D, E, G, J, K, L, N, P, R, S, T, U |
| T/C Measurement Accuracy | ±(0.008% of Reading + 0.006 mV) |
| T/C Source Accuracy | ±(0.008% of Reading + 0.006 mV) |
| T/C Measurement Resolution | 0.1° F and C° |
| T/C Source Resolution | 0.1° F and C° |
| Measure RTD | No |
| Measure Frequency | No |
| Measure Resistance | No |
| Measure Voltage | No |
| Measure Current | No |
| Measure Thermistor | No |
| Programable | Yes |
| Min/Max Memory | No |
| Battery Life | 50 HR |
| Pulse Excitation Compatible | Yes |
| Auto Step/Ramp | Yes |
| Backlit Display | Yes |
| Intrinsically Safe | No |
Product General Attributes | |
| Unique Features | Secondary display of compensated millivolt settings and cold junction temperature |
| Warranty | 3 YEARS |
| Warranty Details | 3 Year Return to Factory Warranty against defects in Materials or Workmanship. |
| Safety Approval | CE |
| Product Weight | 12.1 OUNCES (0.756 LBS) |
| Product Height | 1.60 IN |
| Product Length | 5.63 IN |
| Product Width | 3.00 IN |
| Data Logging | No |
| HTS/Schedule B Number | 9030.39.0100 |
| ECCN Number | 3A992 |
| Calibration Included | Factory Calibration, NIST Calibration |
| Battery Type | AA |
| Power Supply Voltage | Battery Powered |
| Country of Origin | United States |






Reviews