Description
Amik Series Digital Power Meter
AMIK 100 Three Phase Digital Panel Meter
Amik 100 is a compact multifunction instrument which measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces multiple analog panel meters
Application
Amik 100 measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters. It measures electrical parameters like AC Voltage, AC Current, & many more.
Electrical Parameters
| Sr No | Parameter | 3 Phase 4 Wire | 3 Phase 3 Wire | 1 Phase 2 Wire |
| 1 | System Volts | ![]() | ![]() | ![]() |
| 2 | System Current | ![]() | ![]() | ![]() |
| 3 | Frequency | ![]() | ![]() | ![]() |
| 4 | Volts R–N | ![]() | X | ![]() |
| 5 | Volts Y–N | ![]() | X | X |
| 6 | Volts B–N | ![]() | X | X |
| 7 | Volts R-Y | ![]() | ![]() | X |
| 8 | Volts Y–B | ![]() | ![]() | X |
| 9 | Volts B–R | ![]() | ![]() | X |
| 10 | Current R | ![]() | ![]() | ![]() |
| 11 | Current Y | ![]() | ![]() | X |
| 12 | Current B | ![]() | ![]() | X |
| 13 | RPM | ![]() | ![]() | ![]() |
| 14 | Max (System Voltage / System Current) | ![]() | ![]() | ![]() |
| 15 | Min (System Voltage / System Current) | ![]() | ![]() | ![]() |
| 16 | Hour Run | ![]() | ![]() | ![]() |
| 17 | ON Hour | ![]() | ![]() | ![]() |
| 18 | Number of auxiliary interrupt | ![]() | ![]() | ![]() |
Product Features
| On site programmable PT/CT ratios | It is possible to program primary of the external potential Transformer (PT), primary of external Current Transformer (CT) on site via front panel keys by entering into Programming mode. |
| User selectable CT Secondary 5A / 1A | The secondary of external Current Transformer (CT) can be programmed on site to either 5A or 1A using front panel keys. |
| User selectable PT Secondary | The secondary of external Potential Transformer (PT) can be programmed on site from 100VLL to 500VLL using front panel keys. |
| User selectable 3 phase 3Wire 4Wire or Single phase Network | User can program on site the network connection as either 3 Phase 3 Wire/4 Wire or single phase network using front panel keys. In case of self powered configuration either 3 Phase 4 wire or single phase network are available. |
| RPM Measurement | The instrument display Rotation per minutes for generator applications. Number of poles can be set on site depending upon application requirement. |
| Limit switch (Relay) | The instrument will trip the relay if the programmed parameter exceeds the programmed Trip Limits. |
| 3 line 4 digits LED display | Simultaneous display of 3 Parameters. |
| Enclosure Protection for dust and water | Conforms to IP 50 (for front face) or IP 65 option (for front with seal) & IP 20 (for back) & as per IEC60529. |
| Storage of parameters possible | The instrument stores minimum and maximum values for System Voltage, System Current, Run Hour, ON Hour & number of Interrupts. Every 60 sec stored values are updated. |
| Four function keys | Using the four function key, it is possible to go desired parameter screen instantly. |
| Onsite selection of Auto scroll / Fixed Screen | User can set the display in auto scrolling mode or fixed screen mode using front panel keys. |
| Low back depth | The instrument has very low back depth (behind the panel) of less than 55mm (without output options). |
| True RMS measurement | The instrument measures distorted waveform up to 15th Harmonic. |
| EMC Compatibility | Compliance to International standard IEC 61326 |
| Interference Emission | IEC 61326-1 : 2005, Class, A |
| Interference Immunity | IEC 61326-1 : 2005 |
| Electrostatic discharge | IEC 61000-4-2 — 4kV/8kV contact/air. (ESD) |
| EM Field | IEC 61000-4-3 — 10 V/m (80 MHz to 1 GHz) – 3 V/m (1.4 Ghz to 2 GHz) — 1 V/m (2 GHz to 2.7 GHz) |
| Burst | IEC 61000-4-4 — 2 kV (5/50 ns, 5 kHz) |
| Surge | IEC 61000-4-5 — 1 kVLL / 2 kVLN. |
| Conducted RF | IEC 61000-4-5 — 3 V (150 kHz to 80 MHZ) |
| Rated Power Frequency magnetic Field | IEC 61000-4-8 — 30 A/m |
| Voltage dip | IEC 61000-4-1 40% during 10/12 cycles. 70% during 25/30 cycles. |
| Short interruptions | IEC 61000-4-11 0% during 25/30 cycles. 25 cycles for 50 Hz test. 30 cycles for 60 Hz test. |
Dimension Details
| With optional Limit switch | ![]() | ![]() |
Installation
| Easy Clip in Installation on Panel | ![]() |
![]() | |
| Rear Connection | ![]() |
Electrical Connections
| Self Powered Aux | External Powered Aux | |
| 3 Phase 4 Wire Unbalanced Load | ||
| 3 Phase 3 Wire Unbalanced Load | Not Applicable | |
| 1 Phase 2 Wire | ||
| *Note: For Measurement of parameters, Voltage must be present between terminal 2 & 11 for single phase or 3 phase 4 wire network and between terminal 2 & 5 or 2 & 8 for 3 phase 3 wire network. | ||
Temperature / PID Controllers | |
|---|---|
| Size Rectangular | 1/4 DIN |
Panel Meters/Panel Meters Template | |
| Type (Panel Meter ) | Digital |
| Style (Panel Meter) | Rectangular/Square |
| Mounting (Panel Meter) | Panel Mount |
| Input (Panel Meters) | Current, Frequency, Voltage |
Product General Attributes | |
| Warranty | 2 YEARS |
| Safety Approval | UL |
| Product Height | 4.05 IN |
| Product Length | 5.10 IN |
| Product Width | 5.05 IN |
| HTS/Schedule B Number | 9030.31.0000 |
| ECCN Number | EAR99 |
| Calibration Included | Factory Calibration |
| Country of Origin | United States |














Reviews
There are no reviews yet.