Description
TPI 183A True RMS Digital Multi-Meter with Temperature Capacitance

- True RMS for more accurate measurements
- Duty cycle (% pulse width modulation) for measuring modulating gas valves
- Low pass filter for noisy environments
- Separate fuse and battery compartment
- IR serial interface
The TPI 183A is a true RMS auto-ranging Digital Multi-Meter. The backlit LCD can display three readings at one time. In addition to basic functions of ACV, DCV, ACA, DCA, Diode Test and continuity, the 183A measures Frequency (Hz) and Capacitance. The 183A also has RS232 output and software for recording information into a PC.
The 183 is a hand-held autoranging DMM. The backlit LCD can display three readings at one time. In addition to basic functions of ACV, DCV, ACA, DCA, , Diode Test and Continuity, the 183 measures Frequency (Hz) and Capacitance. The 183 also has RS232 output and software for recording information into a PC.
The 183A also features:
- REC – Records Min/Max and Average readings during specified measurement intervals. Time reference can also be displayed to determine when the values were recorded.
- COMP – Compare actual reading to preset HI and LOW values for Pass/Fail testing of components.
- HOLD – Two-hold system automatically holds the previous stable reading when a new one is obtained.
Applications
- Test run and start capacitors
- Measure ambient and duct temp
- Test control (thermostat, thermocouple, flame safety) and line voltages
- Measure resistance and test for continuity
- Line current up to 10 amps (in series)
Multimeters Template | |
---|---|
Style | Hand-Held |
Measures AC V | Yes |
Measures DC V | Yes |
Measures AC A | Yes |
Measures DC A | Yes |
True RMS | Yes |
Maximum Voltage AC | 750 V |
Resolution AC Volts | 0.01 mV |
Maximum Voltage DC | 1000 V |
Resolution DC Volts | 0.01 mV |
Maximum Current AC | 10 A |
Minimum Current AC | 0.1 uA (0.00010 mA) |
Resolution AC Current | 0.1 uA (0.00010 mA) |
Maximum Current DC | 10 A |
Minimum Current DC | 0.01 uA (0.00001 mA) |
Resolution DC Current | 0.01 uA (0.00001 mA) |
Basic Accuracy V DC | .5% |
# Digit Display | 4 |
Counts | 4000 . |
Backlight | Yes |
Manual/Autoranging | Both |
Decibels | No |
Resistance | Yes |
Frequency | Yes |
Capacitance | Yes |
Temperature | Yes Temperature k-type thermocouple and adapter included |
Diode Testing | Yes |
CAT Rating | III |
CAT Voltage | 600 V |
Intrinsically Safe | No |
Peak Hold | Yes |
Overload Protector | Yes |
Kelvin 4-Wire Measurement Capability | No |
Wireless Display | No |
Data Hold | Yes |
Low-Pass Filter | Yes |
Duty Cycle % | 0.1 – 99.9% (0.5Hz to 500kHz, Width > 2uS) |
Product General Attributes | |
Unique Features | true RMS, low pass filter (for transient noise reduction), duty cycle (pulse width modulation), temperature |
Warranty | 3 YEARS |
Safety Approval | CE, UL |
Interfaces I/O | RS-232, USB |
Product Weight | 12 OUNCES (0.75 LBS) |
Product Height | 1.3 IN |
Product Length | 7.4 IN |
Product Width | 3.4 IN |
Shipping Weight | 1.8 LBS |
Data Logging | Yes Data Logging with optional PC software and cable (A183a) |
HTS/Schedule B Number | 9030.31.0000 |
ECCN Number | EAR99 |
Battery Type | AA |
Power Supply Voltage | Battery Powered |
Country of Origin | Korea |
UPC | 637623001833 |