Combustion Efficiency Analyzer with flue probe only

  • Combustion Analyzer with Flue Probe
  • Perform combustion efficiency calculations
  • Driven by pump for fast response
  • For increased safety, will not shut off if 15 ppm CO is present
  • Includes ten selectable fuels
  • Optional IR printer available for reporting
  • Differential thermometer is built-in
  • Storage for up to 50 readings
  • Display is backlit and easy to read
SKU: TPI 708 EAN: 637623007088 Tags: , Categories:
Pay safely with Visa Pay safely with Master Card Pay safely with PayPal Pay safely with Maestro Tooltip text
Guarantee Safe and Secure Payment Checkout

Description

Combustion Efficiency Analyzer with Flue Probe, 3 x 1.5V AA Alkaline Batteries, Backlit LCD Display, 14 to 122 Degree F

The TPI 708 combustion analyzer uses state of the art electrochemical sensors. This sensor technology provides the longest lasting, most accurate and reliable means for performing combustion tests. The sensors in your analyzer will need to be replaced periodically and calibration is recommended once every year. The 708 will remind you when calibration is due by flashing “CAL DUE Err” for three seconds at start up.

Electrochemical sensors by nature are always active. Therefore the time the analyzer is off and not being used must be taken into account when determining sensor life. The sensors in your analyzer are warranted for two years. This warranty does not cover sensors damaged through misuse of the analyzer.

You should keep the batteries of your 708 fresh so power is constantly being supplied to your sensors.

Applications:

• Tuning of residential and furnaces and domestic boilers
• Ambient and stack testing for CO
• CO safety measurements in and around combustion sources
• Temperature checking, including superheat and hydronic differential temperatures

Several factors affect combustion efficiency.

Dirty or clogged air filters reduce the amount of air available for combustion therefore reducing efficiency. Obstructions in the flue block exhaust gases and alter the air mixture in the combustion chamber which reduces efficiency. Air leaks in the combustion chamber also alter the mixture causing decreased efficiency.

The primary way to affect change in combustion efficiency when working with modern gas fired equipment is through gas manifold pressure adjustment.

Confirm manifold pressures are within manufacturers specifications prior to performing a combustion test. Once manifold pressures are within limits a combustion test can be performed to provide information regarding any adjustments that may be needed.

10,000ppm is equal to 1%.

The formula to convert percent to ppm is: ppm = %gas X 10,000. The formula to convert ppm to percent is: % = ppm / 10,000.

The 709, 712, and 714 incorporate a differential manometer.

Pressure applied to the (-) port is subtracted from the pressure applied to the (+) port. Examples of pressures being measured:

(+) port = 10″H²O, (-) port = Not Connected, Displayed reading =10″H²O
(+) port = 10″H²O, (-) port = 5″H²O, Displayed reading = 5″H²O
(+) port = Not Connected, (-) port = 10″H²O, Displayed reading = -10″H²O

Sensor Calibration

The sensors in your analyzer will need to be replaced periodically and calibration is recommended once every year. Electrochemical sensors by nature are always active. Therefore the time the analyzer is off and not being used must be taken into account when determining sensor life. The sensors in your analyzer are warranted for two years. This warranty does not cover sensors damaged through misuse of the analyzer.

Combustion Analyzer Template

Includes NO sensorNo
Includes NO2 sensorNo
Includes printerNo
Includes SO2 sensorNo
Digital deviceYes

Product General Attributes

Unique Featureslow cost combustion efficiency analyzer, kit includes instrument, flue probe, temperature probe and carrying case
Warranty3 YEARS
Warranty Details3 year warranty instrument, 2 years on sensors
Additional Info/Comments0-10,000 PPM CO with +/- 5 ppm accuracy
Interfaces I/O IR
StorageHard Drive
Product Weight500 GRAMS (1.10 LBS)
Product Height90 MM (3.54 IN)
Product Length200 MM (7.87 IN)
Product Width60 MM (2.36 IN)
Shipping Weight4.8 LBS
Data LoggingNo 
HTS/Schedule B Number9027.10.0000
ECCN NumberEAR99
Calibration IncludedFactory Calibration
Battery TypeAA
Power Supply VoltageBattery Powered
Country of OriginKorea
Shipping Height6.25 IN
UPC637623007088
Shipping Length17.30 IN
Shipping Width8.95 IN

Reviews

There are no reviews yet.

Be the first to review “TPI 708 Combustion Efficiency Analyzer with Flue Probe”
Weight500 lbs
Dimensions200 × 60 × 90 in
TPI 708 Combustion Efficiency ...

Original price was: $549.94.Current price is: $505.94.

Our team of knowledgeable professionals is here to help you make informed decisions. Whether you need product recommendations, technical support, or guidance on your purchase, we're just a click away.

Contact Us Now:
📧 sales@nestesinstruments.com
📞 +1 (833) 763-7837


Let us assist you in finding the perfect solution!
Have Questions? Ask an Expert!