Description

Vitrek 964i-8X2MX
- Pre-built 964i w 2 ea 7KV 8 Ch. Cards and a Hipot/Cont Mux Card
- “The 964i rear panel accommodates up to 60 output terminals. Unit shown above with 16 + terminals (HV) and 16 – terminals (return). The 964i ships with mating connectors for all +/- HV terminals 7KV and higher. Custom length HV lead sets are optionally available.”High Voltage Ratings to 3KV, 7KV, 10KV or 15KV
- High Current Ratings to 40 Amps
- Reduces hazardous operator exposure to high-voltage
- Improves test quality, consistency, and repeatability
Multipoint Switching System 2 ea 7KV 8 Ch.
Vitrek High Voltage Switching System – Pre-built 964i with 2xHV7-8 (1 White, 1 Black) Cards and a Hipot/Cont Mux Card. Comes with: Interconnect Lead Set (for connection to Vitrek Tester), Chassis Grounding Cable, VICL-2, 8xHVC-MW, 8xHVC-MB, External Power Supply with Power Cord, Operating Manual, Certificate of Quality.

The 964i High Voltage Switching System is built precisely to meet Your HV Switching requirements
The 964i holds up to 8, eight-channel HV switching cards. That’s up to 64 test points in a single mainframe – multiple units can be combined to increase capacity.
Whether you have to hipot an 8-pin connector, a 64 conductor cable, or an entire tray of SMD capacitors – the 964i has the capacity to automatically route test points to your tester, so you don’t have to. The 964i is easily configured to handle your test specifications. First, select from 4 different voltage ratings – 3KV, 7KV, 10KV and 15KV. Next, decide on how many cards you need. And finally – choose the input, either + (HV bus) or – (return bus) for each card. It’s that simple. If you have any questions, contact a Vitrek application specialist for assistance in configuring your ideal switching solution.
High Voltage Switching doesn’t get any easier
The 964i is simple to set up. Standard front inputs connect directly to your Hipot/Continuity Tester and up to 60 rear panel terminals connect with your test fixture or DUT. Up to four 964i’s can be controlled directly by a single Vitrek 95X or V7X Series Hipot Tester or up to 10 via PC through the 964i’s built-in RS232 (serial) port or available GPIB interface. The 964i’s LCD display confirms system status and switch activation at a glance.
Try the 964i High Voltage Switching Scanner, you will never manually switch again
The Vitrek 964i High Voltage Automated Test Switching System routes high voltage test signals and return signals to any desired test points. This unique capability gives you control over each individual relay, unlike typical cable testers which restrict you to a fixed pattern. With available mux cards, you can also access the matrix with other equipment such as an LCR meter or DMM. The result is a highly repeatable, rapid switching test system with no operator intervention and fully automated data acquisition. With voltage switching capability up to 15,000 volts or current switching as high as 40 amps – the 964i can handle just about any test requirement that comes along. Give it a try, you will never switch back to manual testing again.

“The 964i rear panel accommodates up to 60 output terminals. Unit shown above with 16 + terminals (HV) and 16 – terminals (return). The 964i ships with mating connectors for all +/- HV terminals 7KV and higher. Custom length HV lead sets are optionally available.”
Product General Attributes | |
|---|---|
| Country of Origin | United States |



Reviews