Description
Yokogawa CA71/TE – Handy Calibrator

- High accuracy
- Simultaneous signal generation and measurement capability
- AC voltage (including supply voltage) measurement capability
- A wide array of useful functionsÂ
- Easy Operation
- Compact size and Lightweight
- Loop Power Supply Function
- Output Functions
The CA51/CA71 HANDY CAL calibrators are comprehensive generating/measuring instruments for all your calibration and equipment checking needs at maintenance sites. The CA51/CA71 can simultaneously generate and measure voltage, current, TC, RTD and pulse signals, thus you don’t need to prepare many instruments. In addition, the incorporated rotary switches of good repute enable operations so smooth that an incorrect measurement caused from erroneous operations can be prevented.
Simultaneous Signal Source and Measurement Capability
Â
The CA71 lets you handle regular tests on TCs, RTDs and various other types of sensors and instruments, as well as operation checks when a problem has occurred. By itself it can source signals for input to equipment, and check output signal from equipment. With the CA71, you don’t need to worry about synchronizing operations with other setting devices. (TC and RTD measurement functions are CA71 only.)
AC Voltage (including Supply Voltage) Measurement Capability
Â
In cases where numerous signal converters and other devices are mounted on a rack or panel, the Handy Calibrator can be used to check the input and output signals of each device, while simultaneously checking the power supply. There is no need for a separate multimeter to measure supply voltage
A Wide Array of Useful Functions
Â
- Source: Values set in steps of 4-20 mA 24V DC Power Supply to Transmitter.
- Divided output (n/m) function: Output settings are divided, eliminating the need for bothersome calculations for percentage output.
- Autostep function: Changes the output value in step form based on the setting from the divided output (n/m) function. Changes can be sourced automatically every 10% or 25%.
- Online communication (CA71 only): RS-232C-compliant optically isolated interface
- Sweep function: Linearly increases or decrease the output. The increasing/decreasing time can be set to either 16 or 32 seconds.
- Memory function: Source values and measurements forming individual value sets can be saved to or read from the Handy Calibrator’s internal memory (maximum 50 value sets).
- Temperature monitor function
Easy Operation
Â
The Handy Calibrator incorporates rotary switches for simple handling. Just open the carrying case cover and connect the cables, and you’re ready to take measurements.
Product General Attributes | |
---|---|
Product Weight | 1.61 LBS |
Product Height | 4.72 IN |
Product Length | 2.17 IN |
Product Width | 7.48 IN |
Shipping Weight | 1.85 LBS |
Battery Type | AA |
Reviews