Description
SCI (Slaughter) 448 – 4-in-1 tester with 500VA AC Hipot, DC Hipot, Insulation Resistance and Ground Bond Testing

- 500VA AC hipot output to comply with 100mA leakage current test compliance requirements
- AC hipot – 5kV @ 100mA
- DC hipot – 6kV @ 10mA
- Insulation resistance testing
- Ground bond testing – 40A AC
The SCI (Slaugher) 448 is a 4-in-1 tester with 500VA AC Hipot, DC Hipot, Insulation Resistance and Ground Bond testing capabilities. The 448 is capable of a 500VA AC Hipot output to comply with 100mA leakage current test compliance requirements. This tester features a simple design and easy-to-use interface, reducing setup time and increasing production-line throughput for your application. The 448 is equipped with multiple memories and an optional USB port for remote BUS communication so you can quickly perform tests on a variety of DUTs from the front panel or with a PC. Add to user safety by equipping your tester with Personal Protective Equipment (PPE) via the built-in safety interlock.
Relevant Applications:
- Appliance
- Industrial Equipment
- Information Technology
- Contract Manufacturing
- Laboratory Equipment
Two models available
There are two models in the SCI 440 series. The main features of each can be viewed in the chart below.
![]() | ![]() | ![]() | ![]() | |
| 446 | ● | ● | ● | ● |
| 448 | 500VA | ● | ● | ● |
Front panel controls

- Reset button – momentary contact switch used to reset the tester
- Test button – momentary contact switch used to start a test
- LCD display – main readout for the operator and programmer of the test settings and test results
- High voltage output jack – for connection of the detachable HV test lead or the adapter box HV connector
- Power switch
- Rotary knob – used to advance forward/backward through the setup menus and to setup system and test parameters
- High voltage arrow (LED indicator) – flashes to warn high voltage is present
- Current output terminal – used to attach the high current output lead, adapter box high current lead or test fixture high current lead to the instrument. This connection provides the output current for the ground bond
- Return terminal – used to attach the return test lead, adapter box return lead or test fixture return lead to the instrument. This connection provides the return current path
Rear panel controls

- High voltage output jack – For connection of the detachable HV test lead or the HV adapter box
- Return terminal – Used to attach the return test lead, adapter box return lead or test fixture return lead to the instrument. This connection provides the return current path.
- Current output terminal – Used to attach the high current output lead, adapter box high current lead, or test fixture high current lead to the instrument. This connection provides the output current for the ground bond.
- High voltage arrow (LED indicator) – Flashes to warn the operator that high voltage is present at the high voltage output terminal
- Calibration enable key – To enter the calibration mode, press this key while the tester is being powered on.
- USB connector – USB port for serial communication. Refer to Remote Bus Interface section page 50 in manual
- Remote output – 9 pin D subminiature female connector for monitoring PASS, FAIL, and PROCESSING output relay signals.
- Remote input – 9 pin D subminiature male connector for remote control of test, reset, and interlock functions as well as remote memory tests selection.
- Chassis ground earth terminal
- Fuse receptacle
- Input power receptacle – Standard IEC 320 connector for connection to a standard NEMA style line power mains cord
Safety Testing / Surge Testing/Hipot Tester Template | |
|---|---|
| Test Type Hipot | AC, DC, Ground Bond, IR |
| Max AC Test Voltage | 5 kV |
| Max DC Test Voltage | 6 kV |
| Min AC Test Voltage | 0 V |
| Min DC Test Voltage | 0 V |
| Max Trip Current AC Test | 99.99 mA |
| Min Trip Current AC Test | 0 mA |
| Max Trip Current DC Test | 10 mA |
| Min Trip Current DC Test | 0 mA |
| Programmable (hipot) | Yes |
| Ground Continuity Current AC | 40 A |
| Insulation Resistance Test | Yes |
| IR Test Voltage | 1,000 V, 100 V, 125V, 250 V, 400V, 500 V |
| Arc Detection | No |
| Scanning control capable for Multipoint Testing | No |
| Maximum Insulation Resistance | 1 G Ohms (1000 M Ohms) |
Product General Attributes | |
| Warranty | 5 YEARS |
| Product Weight | 53 LBS |
| Product Height | 5.197 IN |
| Product Length | 15.75 IN |
| Product Width | 16.93 IN |
| Shipping Weight | 60.95 LBS |
| HTS/Schedule B Number | 9030.33.3400 |