AC/DC/IR and GB TESTER 500VA

  • 4-in-1 tester
  • 500VA AC hipot output to comply with 100mA leakage current test compliance requirements
  • AC hipot – 5kV @ 100mA
  • DC hipot – 6kV @ 10mA 
  • Insulation resistance testing
  • Ground bond testing – 40A AC
  • Intuitive user interface
  • 20 programmable memories
  • Remote safety interlock
  • Easy to use – increases production line throughput
Pay safely with Visa Pay safely with Master Card Pay safely with PayPal Pay safely with Maestro Tooltip text
Guarantee Safe and Secure Payment Checkout

Description

SCI (Slaughter) 448 – 4-in-1 tester with 500VA AC Hipot, DC Hipot, Insulation Resistance and Ground Bond Testing

  • 500VA AC hipot output to comply with 100mA leakage current test compliance requirements
  • AC hipot – 5kV @ 100mA
  • DC hipot – 6kV @ 10mA
  • Insulation resistance testing
  • Ground bond testing – 40A AC

The SCI (Slaugher) 448 is a 4-in-1 tester with 500VA AC Hipot, DC Hipot, Insulation Resistance and Ground Bond testing capabilities. The 448 is capable of a 500VA AC Hipot output to comply with 100mA leakage current test compliance requirements. This tester features a simple design and easy-to-use interface, reducing setup time and increasing production-line throughput for your application. The 448 is equipped with multiple memories and an optional USB port for remote BUS communication so you can quickly perform tests on a variety of DUTs from the front panel or with a PC. Add to user safety by equipping your tester with Personal Protective Equipment (PPE) via the built-in safety interlock.

Relevant Applications:

 

  • Appliance
  • Industrial Equipment
  • Information Technology
  • Contract Manufacturing
  • Laboratory Equipment
Two models available

There are two models in the SCI 440 series. The main features of each can be viewed in the chart below.

 
446
448500VA

Front panel controls

  1. Reset button – momentary contact switch used to reset the tester
  2. Test button – momentary contact switch used to start a test
  3. LCD display – main readout for the operator and programmer of the test settings and test results
  4. High voltage output jack – for connection of the detachable HV test lead or the adapter box HV connector
  5. Power switch
  6. Rotary knob – used to advance forward/backward through the setup menus and to setup system and test parameters
  7. High voltage arrow (LED indicator) – flashes to warn high voltage is present
  8. Current output terminal – used to attach the high current output lead, adapter box high current lead or test fixture high current lead to the instrument. This connection provides the output current for the ground bond
  9. Return terminal – used to attach the return test lead, adapter box return lead or test fixture return lead to the instrument. This connection provides the return current path

Rear panel controls

  1. High voltage output jack – For connection of the detachable HV test lead or the HV adapter box
  2. Return terminal – Used to attach the return test lead, adapter box return lead or test fixture return lead to the instrument. This connection provides the return current path.
  3. Current output terminal – Used to attach the high current output lead, adapter box high current lead, or test fixture high current lead to the instrument. This connection provides the output current for the ground bond.
  4. High voltage arrow (LED indicator) – Flashes to warn the operator that high voltage is present at the high voltage output terminal
  5. Calibration enable key – To enter the calibration mode, press this key while the tester is being powered on.
  6. USB connector – USB port for serial communication. Refer to Remote Bus Interface section page 50 in manual
  7. Remote output – 9 pin D subminiature female connector for monitoring PASS, FAIL, and PROCESSING output relay signals.
  8. Remote input – 9 pin D subminiature male connector for remote control of test, reset, and interlock functions as well as remote memory tests selection.
  9. Chassis ground earth terminal
  10. Fuse receptacle
  11. Input power receptacle – Standard IEC 320 connector for connection to a standard NEMA style line power mains cord

Safety Testing / Surge Testing/Hipot Tester Template

Test Type HipotAC, DC, Ground Bond, IR
Max AC Test Voltage5 kV
Max DC Test Voltage6 kV
Min AC Test Voltage0 V
Min DC Test Voltage0 V
Max Trip Current AC Test99.99 mA
Min Trip Current AC Test0 mA
Max Trip Current DC Test10 mA
Min Trip Current DC Test0 mA
Programmable (hipot)Yes
Ground Continuity Current AC40 A
Insulation Resistance TestYes
IR Test Voltage1,000 V, 100 V, 125V, 250 V, 400V, 500 V
Arc DetectionNo
Scanning control capable for Multipoint TestingNo
Maximum Insulation Resistance1 G Ohms (1000 M Ohms)

Product General Attributes

Warranty5 YEARS
Product Weight53 LBS
Product Height5.197 IN
Product Length15.75 IN
Product Width16.93 IN
Shipping Weight60.95 LBS
HTS/Schedule B Number9030.33.3400

Reviews

There are no reviews yet.

Be the first to review “SCI 448 – 4-in-1 tester with 500VA AC Hipot, DC Hipot, Insulation Resistance and Ground Bond Testing”

Manuals/Guides

Weight53 lbs
Dimensions15.75 × 16.93 × 5.197 in
SCI 448 – 4-in-1 tester ...

$5,498.90

Our team of knowledgeable professionals is here to help you make informed decisions. Whether you need product recommendations, technical support, or guidance on your purchase, we're just a click away.

Contact Us Now:
📧 sales@nestesinstruments.com
📞 +1 (833) 763-7837


Let us assist you in finding the perfect solution!
Have Questions? Ask an Expert!