Description
Amprobe 37XR-A – TRMS Digital Multimeter

- Backlight, True-rms with component and logic test
- Inductance to 40 H, frequency to 40 MHz, capacitance to 400 μF, logic to 20 MHz
- Input warning tone when test leads are in wrong jack
- 10 Amps AC/DC, fully safety fused
- Continuity beeper
The Amprobe 37XR-A Digital Multimeter offers True-rms measurement along with component and logic testing for troubleshooting electronics at the bench or on the job site.
Multimeters Template | |
---|---|
Style | Hand-Held |
Measures AC V | Yes |
Measures DC V | Yes |
Measures AC A | Yes |
Measures DC A | Yes |
True RMS | Yes |
Maximum Voltage AC | 750 V |
Resolution AC Volts | 100 uV (0.1 mV) |
Maximum Voltage DC | 1000 V |
Resolution DC Volts | 100 uV (0.1 mV) |
Maximum Current AC | 10 A |
Minimum Current AC | 0.01 uA (0.00001 mA) |
Resolution AC Current | 0.01 uA (0.00001 mA) |
Maximum Current DC | 10 A |
Minimum Current DC | 0.01 uA (0.00001 mA) |
Resolution DC Current | 0.01 uA (0.00001 mA) |
Basic Accuracy V DC | ± 0.1% Rdg + 5D |
# Digit Display | 4.75 |
Counts | 10000 . |
Backlight | Yes |
Manual/Autoranging | Auto-ranging |
Decibels | No |
Resistance | Yes |
Frequency | Yes |
Capacitance | Yes |
Temperature | No |
Diode Testing | Yes |
CAT Rating | IIÂ CAT Rating attribute_type should be multi_select |
CAT Voltage | 1,000 V |
Intrinsically Safe | No |
Peak Hold | Yes |
Overload Protector | Yes |
Kelvin 4-Wire Measurement Capability | No |
Wireless Display | No |
Data Hold | Yes |
Low-Pass Filter | No |
Duty Cycle % | 0% to 90%Â Duty Cycle % attribute_type should be Text |
Product General Attributes | |
Unique Features | Input Warning Tone when Test Leads are in Wrong Jack, 10A Fully Safety Fused, Auto Power Off to Save Battery Life, Separate Door for Easy Battery and Fuse Access |
Warranty | 3 YEARS |
Warranty Details | 3 Years from the Date of Purchase, Shall not be Liable for Loss of use of the Multimeter or other Incidental or Consequential Damages, Expenses or Economical Loss or for any Claim or Claims for such Damage, Expenses or Economical Loss |
Additional Info/Comments | Deluxe Test Lead Kit, Heavy Duty Case, High Voltage Probe, Padded Vinyl Carry Case, High Temperature Probe |
Safety Approval | CSA |
Product Weight | 1 LBS |
Product Height | 7.75 IN |
Product Length | 2.4 IN |
Product Width | 3.55 IN |
Data Logging | No |
HTS/Schedule B Number | 9030.32.0000Â HTS/Schedule B Number Value not available |
ECCN Number | 3A992Â ECCN Number Value not available |
Power Supply Voltage | Battery Powered Power Supply Voltage Battery Operated Device |
Country of Origin | Taiwan |
Other Information | Display: 4 ¾ digit liquid crystal display (LCD) with a 41 segment analog bargraphic. Auto ranging: 9999 counts Manual ranging: 9999 counts Polarity: Automatic, positive implied, negative polarity indication. Overrange: (OL) or (-OL) is displayed. Zero: Automatic. Low battery indication: The indicator is displayed when the battery voltage drops below the operating level. Auto power off: Approx. 30 minutes. Measurement rate: 2 times per second, nominal. Operating environment: 0 ºC to 50 ºC at 70 % R.H. Storage temperature: -20 ºC to 60 ºC, 0 to 80 % R.H. with battery removed from meter. Temperature Coefficient: 0.1 x (specified accuracy) per ºC. (0 ºC to 18 ºC, 28 ºC to 50 ºC). Altitude: (2000 m) 6562 feet Power: Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22. Battery life: 75 hours typical with carbon-zinc. 150 hours typical with alkaline. Using the backlight will decrease battery life. Dimensions: 196 mm (H) x92 mm (W) x60 mm (D). Weight: with battery and holster, 482 grams DC Voltage Ranges: 1000 mV, 10 V, 100 V, 1000 V DC Voltage Accuracy: all ranges ± (0.1 % rdg + 5 dgt) DC Voltage Resolution: 100 µV AC Voltage (45 Hz to 2 kHz) True RMS Ranges: 1000 mV, 10 V, 100 V, 750 V AC Voltage (45 Hz to 2 kHz) True RMS Accuracy: 750 V range: 45 to 1 kHz: ± (2.0 % rdg + 10 dgts) AC Voltage (45 Hz to 2 kHz) True RMS Accuracy: All other ranges, 45 to 500 Hz: ± (1.2 % rdg + 10 dgts) AC Voltage (45 Hz to 2 kHz) True RMS Accuracy: All other ranges, 500 to 2 kHz: ± (2.0 % rdg + 10 dgts) AC Voltage (45 Hz to 2 kHz) True RMS Resolution: 100 µV AC coupled: True RMS specified from 5 % to 100 % of range DC Current Ranges: 100 µ, 1000 µ, 10 mA, 100 mA, 400 mA, 10 A DC Current Accuracy: 100 µ range: ± (0.5 % rdg + 10 dgt) DC Current Accuracy: 1000 uA to 400 mA ranges: ± (0.5 % rdg + 5 dgts) DC Current Accuracy: 10 A range: ± (1.5 % rdg + 10 dgt) DC Current Resolution: 0.01 µA AC Current (45 Hz to 1 kHz) True RMS Ranges: 100 µA, 1000 µA, 10 mA, 100 mA, 400 mA, 10 A AC Current (45 Hz to 1 kHz) True RMS Accuracy: 100 µ to 100 mA ranges: ± (1.5 % rdg + 10 dgts) AC Current (45 Hz to 1 kHz) True RMS Accuracy: 400 mA range: ± (2.0 % rdg + 10 dgts) AC Current (45 Hz to 1 kHz) True RMS Accuracy: 10 A range: ± (2.5 % rdg + 10 dgts) AC Current (45 Hz to 1 kHz) True RMS Resolution: 0.01 µA Resistance Ranges: 1000 ? 10 k? 100 k? 1000 k? 10 M? 40 M? Resistance Accuracy: 1000 ? to 1000 k? ranges: ± (0.5 % rdg + 8 dgts) Resistance Accuracy: 10 M? range: ± (1.0 % rdg + 10 dgts) Resistance Accuracy: 40 M? range: ± (2.0 % rdg + 10 dgts) Logic Test , Logic Type: TTL, CMOS |