Description

Exponential Power SBS-1230S
- Many unit options with wide voltage and current range
- Automatically discharges batteries unmanned without danger of over-discharging
- Continuously holds the current set throughout the test
- LCD screen displays real time voltage, discharge current and capacity/Ah removed
- Units can be slaved with the SBS-8400 and/or other load banks to increase amp draw
Load Bank – 125vdc, 0-300Amps
Constant Current DC Load Bank 125 Vdc 0-300Amps
The only way to know if your stationary batteries will perform to specification is to test them regularly.
NERC standard PRC-005-2 requires that vented lead acid and nickel cadmium (NiCd) systems be discharge tested every six (6) years and valve regulated lead acid (VRLA) batteries every three (3) years. IEEE recommends load testing stationary flooded/vented lead acid and NiCd stationary batteries every five (5 )years and VRLA batteries every 12–18 months.
The SBS-1230S constant current load banks are an easy and affordable way to perform accurate IEEE450 (Vented Lead-Acid), IEEE1106 (Ni-Cad), and IEEE1188 (VRLA) load tests.
These units are quick and easy to set up. They display the voltage, current, and Ah removed from the string during the test. Since this is a constant current load bank, the user also does not have to adjust the current during the test.
These load banks come standard with multiple adjustable stop points and built-in protection to ensure that the batteries are never damaged due to over-discharge.
Built-in Protection
- Audible alarm
- Warning on LCD screen
- High temperature shutdown
- High voltage shutdown
- Over load protection
Battery Testing/Capacity and Load Banks Template | |
---|---|
Max Capacity | 300 A |
Load Step Resolution | 0.01 A |
Min Load Voltage DC | 90 V |
Max Load Voltage DC | 150 V |
Controls | LED screen displays |
Product General Attributes | |
Unique Features | Automatic Stop points |
Warranty | 1 YEARS |
Product Weight | 110 LBS |
Product Height | 25 IN |
Product Length | 36 IN |
Product Width | 9 IN |
Shipping Weight | 165 LBS |
Data Logging | No |
HTS/Schedule B Number | 9030330040 |
ECCN Number | EAR99 |
Calibration Included | |
Battery Type | Ni-Cad, Other Battery Type Can Test VRLA, Ni-Cad, Vented Lead Acid |
Power Supply Voltage | Battery Powered |
Country of Origin | China |
Shipping Height | 25.2 IN |
Shipping Length | 26.4 IN |
Shipping Width | 11.1 IN |
Other Information | DC Voltage Range: 90-150 Vdc DC Current Range (Amps): 0-300A |