Description
Class-A compliance for the most demanding power quality tests
The Fluke 1760 Three-Phase Power Quality Recorder is fully compliant to IEC 61000-4-30 Class-A, for advanced power quality analysis and consistent compliance testing. Designed for analysis of utility and industrial power distribution systems, in medium- and low-voltage networks, this power quality monitor provides the flexibility to customize thresholds, algorithms, and measurement selections. The 1760 power recorder captures the most comprehensive details on user-selected parameters.
Applications
- Detailed disturbance analysis – Perform high-speed transient analysis and uncover root cause of equipment malfunction for later mitigation and predictive maintenance. The fast transient option, with its 6000 V measurement range, allows capture of very short impulses such as lightning strikes.
- Class-A quality-of-service compliance – Validate incoming power quality at the service entrance. Thanks to Class A compliance, the Fluke 1760 allows undisputable verification.
- Event correlation at multiple locations – Utilizing GPS time synchronization, users can quickly detect where a fault occurred first, either inside or outside the facility.
- Galvanic separation and DC coupling – Allows complete measurements on dissimilar power systems. For example troubleshoot UPS systems by simultaneously recording the battery voltage and power output
- Power quality and power load studies – Assess baseline power quality to validate compatibility with critical systems before installation and verify electrical system capacity before adding loads.
 There are four Fluke 1760 models to select from:
Â
Product Feature | Fluke 1760 Basic | Fluke 1760TR Basic | Fluke 1760 | Fluke 1760TR |
Power quality statistics according to EN50160 | • | • | • | • |
Voltage event list (dips, swells and interruptions) | • | • | • | • |
Continuous recording of: | ||||
Voltage | • | • | • | • |
Current | • | • | • | • |
Power P, Q, S | • | • | • | • |
Power factor | • | • | • | • |
kWh | • | • | • | • |
Flicker | • | • | • | • |
Unbalance | • | • | • | • |
Frequency | • | • | • | • |
Voltage and current harmonics to the 50th / Interharmonics | • | • | • | • |
THD | • | • | • | • |
Mains signaling | • | • | • | • |
Triggered recordings | • | • | • | • |
Online mode (Oscilloscope, transients and events) | • | • | • | • |
Fast transient analysis up to 10 MHz |  | • |  | • |
4, 600V voltage probes |  |  | • | • |
4 dual-range flexible current probes (1000 A / 200 A ac) |  |  | • | • |
GPS time sync receiver |  |  | • | • |
Memory | 2 GB Flash memory |
Power Measurement/Power Quality Analyzer Template | |
---|---|
Type (Power Quality) | 3 Phase |
Maximum Voltage AC | 1000 V |
Maximum Voltage DC | 1000 V |
True Power / Work ( W) | Yes |
Apparent Power (VA) | Yes |
Reactive Power (VAR) | Yes |
Measurement Frequency (Power Quality) | 50 Hz, 60 Hz |
Display (Power Quality) | Digital |
Alarms | Yes |
Transient Capture | Yes Transient Capture Sample rate 100 kHz to10 MHz per channel |
Displays Waveform | Yes |
Energy | Yes |
Phasor Diagrams | No |
Power Factor (Power Quality) | Yes |
Harmonics | Yes |
Maximum Harmonics Range | 200Â Maximum Harmonics Range <25 % of VRMS fundamental up to a THD of 50 % |
Current Clamps Included | No |
Class A Compliant | Yes |
Crest Factor | Yes Crest Factor < 3 |
CAT Rating | IV |
Product General Attributes | |
Product Height | 16.25 IN |
Product Length | 20.00 IN |
Product Width | 16.25 IN |
Country of Origin | Germany |
Shipping Height | 16.25 IN |
Shipping Length | 20.00 IN |
Shipping Width | 16.25 IN |
Other Information | Statistical Evaluation: Power quality statistics according to EN50160 and DISDIP tables like ITIC, CEBEMA, ANSI Continuous Recording: Fluke 1760 records rms values together with corresponding minimum and maximum values for:
continuously with the following time aggregations: Triggered Recordings: rms: Aggregation time is adjustable between 10 ms (1/2 cycle), 20ms (1 cycle), 200ms (10/12 cycles) or 3 sec (150/180 cycles). Mains Signalling: Phases and N-conductor, Voltage and current Online Mode: Variable refresh rate. This feature allows verification of instrument set up and delivers a quick overview of oscilloscope, transients and events. Intrinsic uncertainty: refers to reference conditions and is guaranteed for two years Quality system: developed, manufactured as per ISO 9001: 2000 Operating temperature range:: 0 ?C to +50 ?C; 32 ?F to +122 ?F Working temperature range:: -20 ?C to +50 ?C; -4 ?F to +122 ?F Storage temperature range:: 20 ?C to +60 ?C; -4 ?F to 140 ?F Reference temperature:: 23 ?C ? 2 K; 74 ?F ? 2 K Climatic class:: B2 (IEC 654-1), -20 ?C to +50 ?C; -4 ?F to +122 ?F Max. operating altitude:: 2000 m: max. 600 V CAT IV*, power supply: 300 V CAT Environment temperature:: 23 ?C ? 2 K ; 74?F ? 2 K Power supply:: 230 V ? 10 % Power frequency:: 50 Hz / 60 Hz Signal:: declared input voltage Udin Averaging:: 10 minute intervals Housing: insulated, robust plastics housing Emission:: Class-A as per IEC/EN 61326-1 Immunity:: IEC/EN 61326-1 Range:: AC: 83 V to 264 V, 45 to 65 Hz Safety:: IEC/EN 61010-1 2nd edition Power consumption:: max. 54VA Battery pack:: NIMH, 7.2 V, 2.7 Ah  : Fluke 1760 features LED indicators for the status of the 8 channels, phase sequence, power supply (mains or accumulator), memory usage, time synchronization, and data transfer. Power LED:: ? Permanent light: normal power supply from mains. Channel LEDs: 3-color LEDs per channel for: Data memory: 2 GB Flash memory depending on model Memory model: Linear Interfaces: Ethernet (100MB/s), compatible to Windows? 98/ME/NT/2000/XP RS 232, external modem via RS 232 Baud rate for RS 232: 9600 Baud to 115 kBaud Dimensions: 325 mm x 300 m x 65 mm; 2.8 x 11.8 x 2.6 in. (H x W x D) Weight: appr. 4.9 kg; 10.8 lbs. (without accessories) Warranty: 2 years Calibration interval: 1 year recommended for Class-A, otherwise 2 years Range for 50 Hz systems: 50 Hz ? 15 % (42.5 Hz to 57.5 Hz) Range for 60 Hz systems: 60 Hz ? 15 % (51 Hz to 69 Hz) Resolution: 16 ppm Sampling frequency for 50 Hz power frequency: 10.24 kHz, The sampling rate is synchronized to mains frequency. Uncertainty for frequency measurements: 20 ppm Uncertainty of internal clock: 1s / day  : Aggregation of the interval values as per IEC 61000-4-30 Class-A Min-, Max-values:: Half cycle, e.g.: 10 ms rms values at 50Hz Transients:: Sample rate 100 kHz to 10 MHz per channel Harmonics: as per IEC 61000-4-7:2002: 200 ms Flicker: as per EN 61000-4-15:2003: 10 min (Pst), 2 h (Plt) Number of inputs: 8 galvanically isolated inputs for voltage and current measurements. Sensor safety: up to 600 V CAT IV depending on sensor Basic safety: 300 V CAT III Nominal voltage (rms): 100 mV Range (peak value): 280 mV Overload capacity (rms): 1000 V, continuously Voltage rise rate: max. 15 kV / ?s Input resistance: 1 MO Input capacitance: 5 pF Input filter: Each channel is equipped with a passive low-pass filter, an anti-aliasing filter and a 16-bit A/D converter. All channels are sampled synchronously with a common quartz-controlled clock pulse. |
Reviews
There are no reviews yet.